Installation

54

 

7

2.

Select a suitable location for the disinfection system and its related components. As it is recommended to install a GFCI, 
make sure that this is taken into consideration prior to any installation. The system can either be installed vertically (inlet 
port at the bottom) as shown in 

Figure 3

 

A

, or horizontally as shown in 

Figure 3

 

B

. However, the vertical installation is 

the most preferred method. When selecting a mounting location, leave enough space to allow the removal of the UV 
lamp and/or quartz sleeve (typically leave a space equal to the size of the chamber itself).

3.

Mount the system to the wall using the supplied clamps. Various connection methods can be used to connect the water 
source to the system, however union type connectors are recommended. The use of a flow restrictor device will help to 
maintain the manufacturers rated flow. The flow restrictor should be installed on the outlet port and is designed to be 
installed in one direction only. Ensure that the flow of the water matches the flow direction as indicated on the flow 
restrictor. Refer to 

Figure 4

.

Note: DO NOT solder connections while attached to the system as this could damage the O-ring seals.

4.

Mount the VIQUA ICE controller horizontally to the wall, near the chamber. Ideally place the controller above the 
chamber and away from any water connection point, to prevent any water from potentially leaking onto the controller by 
means of a leak at a connection point or a “sweating” system. Make sure you allow for a “drip-loop” as shown in 

Figure 5

 

on the lamp, sensor, and power cord, again, to prevent any water from potentially entering the controller.

Figure 3 Disinfection Installation - Vertical and Horizontal

Figure 4 Flow Restrictor

A

B

Unit overall length

Min. clearance equal

to unit overall length

Unit overall length

Min. clearance equal

to unit overall length

Flow

restrictor

Optional temparature

management valve

Flow

Funcionamiento 

5.2 Sistemas Plus que incorporan el controlador BA-ICE-CM

5.2.1 Intensidad UV (%)

 Los productos VIQUA de la serie Plus incorporan un sensor UV que detecta la longitud de onda discreta de 

254 nm de la lámpara UV. Esta información se transmite al controlador VIQUA y es la indicación predeterminada en "% de 
salida de UV". El sistema indica la salida de UV entre el 50 y el 99 %. Cuando el sistema esté por debajo del 50 %, 
aparecerá un aviso de bajo nivel de UV como 

, que parpadeará de forma alterna (a intervalos de 2 segundos) hasta 

llegar al nivel real de UV. P. ej. 

. Además, el sistema emitirá un tono audible intermitente (que se encenderá y apagará 

a intervalos de 2 segundos) durante las condiciones de bajo nivel de UV.

Nota: Niveles de UV de

APLAZAMIENTO

: para aplazar temporalmente la alarma acústica y reactivar la válvula de solenoide (si se ha instalado) 

durante una alarma de nivel bajo de UV, mantenga pulsado el botón de reinicio del temporizador durante cinco segundos. 
Con esto se silenciará la condición de alarma acústica y se activará la salida de solenoide durante 12 horas.

Temperatura demasiado elevada

: cuando la temperatura del agua que hay dentro de la cámara del reactor UV supere 

la clasificación máxima del sistema UV (40 °C), en la pantalla del controlador aparecerá "Ot". Esto suele deberse 

a períodos prolongados sin flujo de agua. Para solucionar esta condición, solo tiene que abrir un grifo y dejar que entre 
agua en el sistema.

Posibles causas de condiciones de alarma de nivel bajo de UV:

a.

Es posible que la lámpara UV haya alcanzado un nivel en el que ya no se pueda obtener un nivel suficiente de 
desinfección debido al tiempo de uso (> 9.000 horas). Se deberá sustituir la lámpara por otra del fabricante del 
mismo tamaño y tipo.

b.

La vaina tubular de cuarzo o la ventana del sensor se han manchado o ensuciado. Esto podría deberse a los 
sedimentos o depósitos minerales presentes en el agua que no se detectaron durante el análisis inicial del agua. 
Consulte 

Sección 4.2

.

c.

Una caída de tensión intermitente en el controlador doméstico que reduce la salida de la lámpara. La lámpara 
volverá a su estado normal al llegar a la tensión máxima.

Nota: El sistema de supervisión no funciona durante las caídas en el suministro eléctrico.

d.

La calidad del agua de entrada ha cambiado y ya no se encuentra dentro del rango de funcionamiento aceptable del 
sistema UV. Realice un análisis del agua para determinar los componentes exactos y los niveles de concentración.

e.

El sensor UV no está correctamente instalado.

5.2.2 Vida restante de la lámpara (días)

 Para obtener esta lectura, pulse una vez el botón de reinicio del temporizador y siga los pasos que se describen 

en la 

Sección 5.1.3

, en relación al uso de esta función.

 para 

Indica que el sistema funciona dentro de un rango de funcionamiento normal.

 para 

Indica que el nivel de UV sigue estando dentro de los niveles seguros, pero podría necesitarse pronto 
una limpieza o una sustitución de lámpara o vaina tubular.

 para 

Indica que el nivel de UV se acerca a un punto de intensidad de UV poco seguro y que se debe realizar 
un servicio inmediato en el sistema UV.

 < 

Indica que se ha alcanzado un nivel de UV poco seguro. En este nivel, el agua no debe consumirse. Se 
debe examinar el sistema o el suministro de agua para determinar la causa de que el nivel de 
intensidad de UV sea tan bajo. En este nivel, la salida de solenoide se ha activado y si hay instalado un 
solenoide, el agua dejará de fluir.

Summary of Contents for VH200

Page 1: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Page 2: ...reclamación bajo garantía necesitará su factura original o bien deberá haber completado y enviado su tarjeta de registro de producto por correo postal o en línea Cobertura específica de la garantía La cobertura de la garantía es específica de la gama de productos de VIQUA La cobertura de la garantía está sujeta a las condiciones y limitaciones establecidas en la sección Condiciones y limitaciones ...

Page 3: ...l if you are in doubt as to whether the outlet is properly grounded DO NOT modify the plug provided with this system if it does not fit in the outlet have a proper outlet installed by a qualified electrician DO NOT use any type of adapter with this system GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code NFPA 70 and to provide additional protection from the ri...

Page 4: ...r yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations CFR requirements including Title 21 Chapter 1 Subchapter J Radiological Health Re...

Page 5: ...uales se llene de cloro lejía antes de que el agua salga del sistema UV Para funcionar de manera eficaz el sistema de desinfección debe tener un sistema de distribución libre de bacterias Consultar la Sección 3 2 Posible entrada de sedimentos a través del pre filtro Analice el agua de suministro para descartar la turbiedad es posible que necesite un filtrado escalonado para recoger todos los sedim...

Page 6: ...fection System Note UV system should be the final piece of treatment equipment Optional flow restrictor Note Mandatory for NSF credited systems Optional water softener To drain Optional by pass assembly Optional by pass assembly Optional by pass assembly Optional solenoid valve Hot water pipes Cold water pipes Customer supplied GFCI circuit to match voltage Water meter Main water shut off 5 Micron...

Page 7: ...2 segundos durante las condiciones de bajo nivel de UV Nota Niveles de UV de APLAZAMIENTO para aplazar temporalmente la alarma acústica y reactivar la válvula de solenoide si se ha instalado durante una alarma de nivel bajo de UV mantenga pulsado el botón de reinicio del temporizador durante cinco segundos Con esto se silenciará la condición de alarma acústica y se activará la salida de solenoide ...

Page 8: ... que sustituir la lámpara de 365 días a 1 día Al llegar a 0 días el controlador mostrará y emitirá un chirrido intermitente 1 segundo encendido 5 segundos apagado para indicar la necesidad de cambiar la lámpara 5 1 2 Interpretación del código A3 APLAZAMIENTO cuando aparece en la pantalla LED el mensaje de fin de la vida útil de la lámpara o A3 la alarma acústica se puede aplazar hasta 4 veces sepa...

Page 9: ...are present Replace the UV lamp annually or biennially if seasonal home use to ensure maximum disinfection Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures N O T I C E Reset lamp life timer after lamp replacement Refer to Section 5 1 3 Refer to www lamprecycle org for lamp disposal Do not use water during replacement of UV lamp 5...

Page 10: ...ED display will read once again 10 51 Maintenance Procedimiento Nota Tras reemplazar la lámpara UV o la vaina tubular de cuarzo realice el procedimiento de desinfección y consulte la Sección 3 2 1 Drene la cámara usando el puerto de drenaje 2 1 2 3 Quite la tuerca de retención el muelle flotante y la junta tórica de la parte inferior 3 1 2 Quite la tuerca de retención y la junta tórica de la parte...

Page 11: ... la vaina tubular de la lámpara Esta capa debe retirarse porque reduce la cantidad de luz UV que llega al agua reduciendo de este modo el rendimiento de la desinfección Si la vaina tubular no puede limpiarse deberá reemplazarse por otra Requisitos previos Cortar el suministro de agua y drenar todas las líneas Quitar la lámpara UV Consulte Sección 4 1 1 Corte la línea de agua de la cámara y libere ...

Page 12: ...or de intensidad UV de 254 nm tenga en cuenta que la introducción de la solución de lejía requerida para efectuar la desinfección provocará una condición temporal de bajo nivel de UV Esto se debe a que la lejía enturbia físicamente el agua no potable Una vez que la lejía circule por el sistema la condición de alarma volverá al estado normal Durante el proceso de desinfección la condición de alarma...

Page 13: ...optimum protection against microbiological contamination in water DO NOT disregard the warning signals The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis Instalación 5 Instale la lámpara UV Consulte Sección 4 1 6 Cuando se hayan realizado todas las conexiones de tuberías conecte el suministro de agua lentame...

Page 14: ...tes the UV level is still within a safe level however cleaning or lamp sleeve replacement may soon be required to Indicates the UV level is nearing the point of unsafe UV intensity UV system should be immediately serviced Indicates the UV level has now reached a level that is unsafe At this level the water should not be consumed The system water supply should be examined to determine the reason fo...

Page 15: ...oque un peligro de incendio Es muy recomendable usar bucles de goteo en los cables conectados al controlador Consulte Figura 5 El sistema de agua completo incluidos los depósitos de presión o agua caliente se deben esterilizar antes de la puesta en marcha Para ello enjuague con cloro lejía doméstica para destruir toda contaminación residual Consulte Sección 3 2 El sistema de desinfección está dise...

Page 16: ...tem should not be installed on a circuit which is incorporated into a light switch Lamp Failure Alarm on New Lamp Loose connection between lamp and connector Disconnect lamp from connector and reconnect ensuring that a tight fit is accomplished Moisture build up in connector may keep lamp and connector from making a solid connection Eliminate chance of any moisture getting to the connector and or ...

Page 17: ...l debido la exposición a rayos UV es recomendable usar accesorios metálicos y canalización de cobre de al menos 25 4 cm en la salida de la cámara UV AVISO La lámpara UV en el interior del sistema de desinfección tiene una clasificación nominal con una vida eficaz de aproximadamente 9000 horas Para garantizar una protección continua reemplace la lámpara UV una vez al año Los niños no deben usar el ...

Page 18: ...surización segura Este símbolo indica que se requiere el uso de botas de seguridad Este símbolo indica que el sistema está bajo presión Este símbolo indica que el operador debe leer toda la documentación disponible para realizar los procedimientos requeridos Este símbolo indica que existe peligro de exposición a rayos UV Se debe usar protección adecuada Este símbolo indica que el fontanero debe us...

Page 19: ...rcionarle años de funcionamiento sin problemas con un mínimo mantenimiento para proteger su agua potable contra contaminantes microbiológicos Para garantizar la continua desinfección del agua las lámparas UV se deben reemplazar cada año por repuestos VIQUA de fábrica Las lámparas VIQUA son fruto de un extenso desarrollo que ha resultado en una plataforma de desinfección altamente eficaz con un ren...

Page 20: ...e date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty for UV lamps Sleeves and UV Sensors VIQUA warrants UV lamps sleeves and UV sensors to be free from defects in material and workmanship for a period of one 1 year from the date...

Page 21: ...This page intentionally left blank ...

Page 22: ...This page intentionally left blank ...

Page 23: ...This page intentionally left blank ...

Page 24: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Reviews: