background image

Section 8

Specifications

8.1 Home and Professional - Standard

Model

VH200

VH410

VP600

VP950

F

low R

a

te

US Public Health 16 
mJ/cm

2

 @ 95% UVT

16 gpm (60 lpm) (3.6 m

3

/hr)

34 gpm (130 lpm) (7.8 m

3

/hr) 

40 gpm (151 lpm) (9.1 m

3

/hr)

60 gpm (230 lpm) (13.7 m

3

/hr)

VIQUA Standard 30 
mJ/cm

2

 @ 95% UVT

9 gpm (34 lpm) (2.0 m

3

/hr)

18 gpm (70 lpm) (4.2 m

3

/hr)

30 gpm (113 lpm) (6.7 m

3

/hr)

46 gpm (175 lpm) (10.5 m

3

/hr

NSF/EPA 40mJ/cm

2

 

@ 95% UVT

7 gpm (26 lpm) (1.6 m

3

/hr)

14 gpm (54 lpm) (3.3 m

3

/hr)

22 gpm (83 lpm) (5.0 m

3

/hr)

35 gpm (133 lpm) (8.0 m

3

/hr)

Dime

nsions

Chamber

45 cm x 8.9 cm (17.8" x 3.5")

59.6 cm x 8.9 cm

(23.5" x 3.5")

78 cm x 8.9 cm (30.7" x 3.5")

114 cm x 8.9 cm (45.2" x 3.5")

Controller 100-250 
VAC

17.2 cm x 8.1 cm x 6.4 cm

(6.8" x 3.2" x 2.5")

17.2 cm x 8.1 cm x 6.4 cm

(6.8" x 3.2" x 2.5")

22.3 cm x 8.1 cm x 6.4 cm

(8.8" x 3.2" x 2.5")

22.3 cm x 8.1 cm x 6.4 cm

(8.8" x 3.2" x 2.5")

Inlet/Outlet Port Size

Combo 3/4” FNPT/1” MNPT

Combo 3/4” FNPT/1” MNPT

1" MNPT

1.5" MNPT

Shipping Weight

5.4 kg (12 lbs)

7.7 kg (17 lbs)

8.6 kg (19 lbs)

13.1 kg (29 lbs)

Electrical

Voltage

100-240V/50-60Hz

100-240V/50-60Hz

100-240V/50-60Hz

100-240V/50-60Hz

Power Consumption

35 W

60 W

78 W

110 W

Lamp Watts

25 W

46 W

58 W

90 W

Total Running Time

Yes

Yes

Yes

Yes

Maximum Operating 
Pressure

8.62 bar (125 psi)

8.62 bar (125 psi)

8.62 bar (125 psi)

8.62 bar (125 psi)

Ambient Water 
Temperature

2-40 ºC (36-104 ºF)

2-40 ºC (36-104 ºF)

2-40 ºC (36-104 ºF)

2-40 ºC (36-104 ºF)

Lamp Type

Sterilume™-HO (high-output)

Sterilume™-HO (high-output)

Sterilume™-HO (high-output)

Sterilume™-HO (high-output)

Visual “Power-On”

Yes

Yes

Yes

Yes

Audible Lamp Failure

Yes

Yes

Yes

Yes

Lamp Replacement 
Reminder

Yes

Yes

Yes

Yes

Visual Lamp Life 
Remaining

Yes

Yes

Yes

Yes

Total Running Time

Yes

Yes

Yes

Yes

Chamber Material

304 SS

304 SS

304 SS

304 SS

Información de seguridad

Sección 1

Información de seguridad

Lea este manual en su totalidad antes de usar este equipo. Preste atención a todas las declaraciones de peligro, 
advertencia y precaución que figuran en este manual. No hacerlo podría resultar en lesiones graves o daños al equipo.

Asegúrese de no dañar la protección que proporciona el equipo. NO use ni instale este equipo de manera distinta de la 
especificada en el manual de instalación.

1.1 Peligros potenciales:

Lea todos los rótulos y etiquetas incluidos en el sistema. Si no se respetan, podrían producirse lesiones o daños al sistema.

1.2 Precauciones de seguridad:

Residuos de aparatos eléctricos y electrónicos (RAEE). Este símbolo 
indica que no debe desechar residuos de aparatos eléctricos 

y electrónicos (RAEE) en la basura. Para su eliminación adecuada, 
póngase en contacto con su centro de reciclaje/reutilización o de 
desechos peligrosos.

Este símbolo indica que no se debe almacenar material combustible o 
inflamable cerca del sistema.

Este símbolo indica que hay presencia de mercurio.

Este símbolo indica que el contenido del paquete de transporte es frágil 

y que el paquete se debe manipular con cuidado.

Este es el símbolo de alerta de seguridad. Para evitar lesiones 
potenciales, respete todos los mensajes de seguridad que siguen a este 
símbolo. En el equipo, consulte el manual de funcionamiento 

y mantenimiento para obtener información adicional sobre la seguridad.

Este símbolo indica que se requiere el uso de gafas de seguridad con 
protección lateral para proteger contra la exposición a rayos UV.

Este símbolo indica que existe un riesgo de descarga eléctrica 

o electrocución.

Este símbolo indica que se requiere el uso de guantes.

Este símbolo indica que es posible que el equipo marcado contenga un 
componente que se podría expulsar con fuerza. Respete todos los 
procedimientos para realizar la despresurización segura.

Este símbolo indica que se requiere el uso de botas de seguridad.

Este símbolo indica que el sistema está bajo presión.

Este símbolo indica que el operador debe leer toda la documentación 
disponible para realizar los procedimientos requeridos.

Este símbolo indica que existe peligro de exposición a rayos UV. Se debe 
usar protección adecuada.

Este símbolo indica que el fontanero debe usar canalizaciones de cobre.

Este símbolo indica que el artículo marcado podría estar caliente y no se 
debe tocar sin tomar las precauciones necesarias.

Este símbolo indica que el sistema se debe conectar únicamente a un 
receptáculo de control adecuadamente conectado a tierra y protegido con 
un interruptor de circuito de fallos de conexión a tierra (GFCI).

Este símbolo indica que existe el potencial de agua MUY caliente cuando 
se inicie el flujo.

Advertencia:

 Este producto puede contener productos químicos que, según considera el Estado de California, pueden provocar cáncer, deformaciones congénitas 

u otros problemas reproductivos.

P E L I G R O

El incumplimiento de estas instrucciones puede ocasionar lesiones graves o la muerte.

  •

Descarga eléctrica:

 Para evitar posibles descargas eléctricas, se deben tomar precauciones debido a la presencia de agua cerca de los equipos 

eléctricos. A menos que surja una situación que se indique explícitamente en las secciones de mantenimiento y solución de problemas, NO intente realizar 
reparaciones usted mismo. Póngase en contacto con un proveedor de servicio autorizado.

  •

CONEXIÓN A TIERRA: 

Este producto se debe conectar a tierra. En el caso de que se produzca un fallo o una avería, la conexión a tierra proporciona una 

ruta de menor resistencia de la corriente eléctrica para reducir el riesgo de descarga eléctrica. Este sistema viene equipado con un cable con conductor y 
toma de conexión a tierra. La toma se debe enchufar a una toma de corriente instalada correctamente, con conexión a tierra, de acuerdo con las leyes y 
normativas locales. La conexión inadecuada del conductor de conexión a tierra del equipo puede resultar en riesgo de electrocución. Si tiene dudas sobre 
si la toma de corriente está conectada a tierra correctamente, consulte con un electricista o personal de servicio cualificado. NO modifique la toma que se 
suministra con este sistema. Si no cabe en la toma de corriente, solicite a un electricista cualificado que cambie la toma de corriente. NO use ningún tipo de 
adaptador con este sistema.

  •

PROTECCIÓN DE INTERRUPTOR DE CIRCUITO DE FALLOS DE CONEXIÓN A TIERRA:

 Para cumplir con el Código Eléctrico Nacional (NFPA 70) de 

Estados Unidos y proporcionar protección adicional contra el riesgo de descarga eléctrica, este sistema se debe conectar únicamente a un receptáculo de 
control adecuadamente conectado a tierra y protegido mediante un interruptor de circuito de fallos de conexión a tierra (GFCI). Inspeccione el 
funcionamiento del GFCI según el programa de mantenimiento sugerido por el fabricante.

  •

NO use el sistema de desinfección si su cable o toma está dañado, si no funciona correctamente o si se ha caído o dañado de algún modo.

  •

No use el sistema de desinfección para propósitos distintos de los previstos (aplicaciones de agua potable). El uso de accesorios no recomendados o 
comercializados por el fabricante o distribuidor pueden provocar condiciones inseguras.

  •

NO instale el sistema de desinfección en una ubicación en la que quedará expuesto a la intemperie o a temperaturas bajo cero.

  •

NO almacene este sistema de desinfección en una ubicación en la que quedará expuesto a la intemperie.

  •

NO almacene este sistema de desinfección en una ubicación en la que quedará expuesto a temperaturas bajo cero, a menos que el agua se haya drenado 
y el suministro de agua se haya desconectado.

Hg

UV

Cu

18

 

43

Specifications

Summary of Contents for VH200

Page 1: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Page 2: ...reclamación bajo garantía necesitará su factura original o bien deberá haber completado y enviado su tarjeta de registro de producto por correo postal o en línea Cobertura específica de la garantía La cobertura de la garantía es específica de la gama de productos de VIQUA La cobertura de la garantía está sujeta a las condiciones y limitaciones establecidas en la sección Condiciones y limitaciones ...

Page 3: ...l if you are in doubt as to whether the outlet is properly grounded DO NOT modify the plug provided with this system if it does not fit in the outlet have a proper outlet installed by a qualified electrician DO NOT use any type of adapter with this system GROUND FAULT CIRCUIT INTERRUPTER PROTECTION To comply with the National Electrical Code NFPA 70 and to provide additional protection from the ri...

Page 4: ...r yank cord to pull plug from outlet Always grasp the plug and pull to disconnect SYSTEM PROTECTION To protect your Controller a UL1449 certified or equivalent transient voltage surge suppressor is strongly recommended The UV lamp in this system conforms to the applicable provisions of the Code of Federal Regulations CFR requirements including Title 21 Chapter 1 Subchapter J Radiological Health Re...

Page 5: ...uales se llene de cloro lejía antes de que el agua salga del sistema UV Para funcionar de manera eficaz el sistema de desinfección debe tener un sistema de distribución libre de bacterias Consultar la Sección 3 2 Posible entrada de sedimentos a través del pre filtro Analice el agua de suministro para descartar la turbiedad es posible que necesite un filtrado escalonado para recoger todos los sedim...

Page 6: ...fection System Note UV system should be the final piece of treatment equipment Optional flow restrictor Note Mandatory for NSF credited systems Optional water softener To drain Optional by pass assembly Optional by pass assembly Optional by pass assembly Optional solenoid valve Hot water pipes Cold water pipes Customer supplied GFCI circuit to match voltage Water meter Main water shut off 5 Micron...

Page 7: ...2 segundos durante las condiciones de bajo nivel de UV Nota Niveles de UV de APLAZAMIENTO para aplazar temporalmente la alarma acústica y reactivar la válvula de solenoide si se ha instalado durante una alarma de nivel bajo de UV mantenga pulsado el botón de reinicio del temporizador durante cinco segundos Con esto se silenciará la condición de alarma acústica y se activará la salida de solenoide ...

Page 8: ... que sustituir la lámpara de 365 días a 1 día Al llegar a 0 días el controlador mostrará y emitirá un chirrido intermitente 1 segundo encendido 5 segundos apagado para indicar la necesidad de cambiar la lámpara 5 1 2 Interpretación del código A3 APLAZAMIENTO cuando aparece en la pantalla LED el mensaje de fin de la vida útil de la lámpara o A3 la alarma acústica se puede aplazar hasta 4 veces sepa...

Page 9: ...are present Replace the UV lamp annually or biennially if seasonal home use to ensure maximum disinfection Always drain the chamber when closing a seasonal home or leaving the unit in an area subject to freezing temperatures N O T I C E Reset lamp life timer after lamp replacement Refer to Section 5 1 3 Refer to www lamprecycle org for lamp disposal Do not use water during replacement of UV lamp 5...

Page 10: ...ED display will read once again 10 51 Maintenance Procedimiento Nota Tras reemplazar la lámpara UV o la vaina tubular de cuarzo realice el procedimiento de desinfección y consulte la Sección 3 2 1 Drene la cámara usando el puerto de drenaje 2 1 2 3 Quite la tuerca de retención el muelle flotante y la junta tórica de la parte inferior 3 1 2 Quite la tuerca de retención y la junta tórica de la parte...

Page 11: ... la vaina tubular de la lámpara Esta capa debe retirarse porque reduce la cantidad de luz UV que llega al agua reduciendo de este modo el rendimiento de la desinfección Si la vaina tubular no puede limpiarse deberá reemplazarse por otra Requisitos previos Cortar el suministro de agua y drenar todas las líneas Quitar la lámpara UV Consulte Sección 4 1 1 Corte la línea de agua de la cámara y libere ...

Page 12: ...or de intensidad UV de 254 nm tenga en cuenta que la introducción de la solución de lejía requerida para efectuar la desinfección provocará una condición temporal de bajo nivel de UV Esto se debe a que la lejía enturbia físicamente el agua no potable Una vez que la lejía circule por el sistema la condición de alarma volverá al estado normal Durante el proceso de desinfección la condición de alarma...

Page 13: ...optimum protection against microbiological contamination in water DO NOT disregard the warning signals The best way to ensure optimum UV performance is to have the water microbiologically tested by a recognized testing agency on a regular basis Instalación 5 Instale la lámpara UV Consulte Sección 4 1 6 Cuando se hayan realizado todas las conexiones de tuberías conecte el suministro de agua lentame...

Page 14: ...tes the UV level is still within a safe level however cleaning or lamp sleeve replacement may soon be required to Indicates the UV level is nearing the point of unsafe UV intensity UV system should be immediately serviced Indicates the UV level has now reached a level that is unsafe At this level the water should not be consumed The system water supply should be examined to determine the reason fo...

Page 15: ...oque un peligro de incendio Es muy recomendable usar bucles de goteo en los cables conectados al controlador Consulte Figura 5 El sistema de agua completo incluidos los depósitos de presión o agua caliente se deben esterilizar antes de la puesta en marcha Para ello enjuague con cloro lejía doméstica para destruir toda contaminación residual Consulte Sección 3 2 El sistema de desinfección está dise...

Page 16: ...tem should not be installed on a circuit which is incorporated into a light switch Lamp Failure Alarm on New Lamp Loose connection between lamp and connector Disconnect lamp from connector and reconnect ensuring that a tight fit is accomplished Moisture build up in connector may keep lamp and connector from making a solid connection Eliminate chance of any moisture getting to the connector and or ...

Page 17: ...l debido la exposición a rayos UV es recomendable usar accesorios metálicos y canalización de cobre de al menos 25 4 cm en la salida de la cámara UV AVISO La lámpara UV en el interior del sistema de desinfección tiene una clasificación nominal con una vida eficaz de aproximadamente 9000 horas Para garantizar una protección continua reemplace la lámpara UV una vez al año Los niños no deben usar el ...

Page 18: ...surización segura Este símbolo indica que se requiere el uso de botas de seguridad Este símbolo indica que el sistema está bajo presión Este símbolo indica que el operador debe leer toda la documentación disponible para realizar los procedimientos requeridos Este símbolo indica que existe peligro de exposición a rayos UV Se debe usar protección adecuada Este símbolo indica que el fontanero debe us...

Page 19: ...rcionarle años de funcionamiento sin problemas con un mínimo mantenimiento para proteger su agua potable contra contaminantes microbiológicos Para garantizar la continua desinfección del agua las lámparas UV se deben reemplazar cada año por repuestos VIQUA de fábrica Las lámparas VIQUA son fruto de un extenso desarrollo que ha resultado en una plataforma de desinfección altamente eficaz con un ren...

Page 20: ...e date of purchase During this time VIQUA will repair or replace at its option any defective parts covered by the warranty Please return the defective part to your dealer who will process your claim One Year Limited Warranty for UV lamps Sleeves and UV Sensors VIQUA warrants UV lamps sleeves and UV sensors to be free from defects in material and workmanship for a period of one 1 year from the date...

Page 21: ...This page intentionally left blank ...

Page 22: ...This page intentionally left blank ...

Page 23: ...This page intentionally left blank ...

Page 24: ...f 1 519 763 5069 Courriel info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canadá N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 solo EE UU y Canadá t 31 73 747 0144 solo Europa f 1 519 763 5069 correo electrónico info viqua com www viqua com 425 Clair Rd W Guelph Ontario Canada N1L 1R1 t 1 519 763 1032 f 1 800 265 7246 US and Canada only t 31 73 747 0144 Europe only f 1 519 763 5069 e mail i...

Reviews: