3.
A new job may be started with
JOB_DONE
= TRUE.
4.
A value to be read of a read job may be found in
JOB_OVAL
in
the instance DB at address 28.
Continuous count:
Job
Valid range
Writing counter directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing hysteresis
0 ... 255
Writing pulse duration*
0 ... 510ms
Single/periodic count, no main count direction:
Job
Valid range
Writing counter directly
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing the load value
-2147483647 (-2
31
+1) ... +2147483646 (2
31
-2)
Writing comparison value
-2147483648 (-2
31
) ... +2147483647 (2
31
-1)
Writing hysteresis
0 ... 255
Writing pulse duration*
0 ... 510ms
Single/periodic count, main count direction up:
Job
Valid range
End value
2 ... +2147483646 (2
31
-1)
Writing counter directly
-2147483648 (-2
31
) ... end value -2
Writing the load value
-2147483648 (-2
31
) ... end value -2
Writing comparison value
-2147483648 (-2
31
) ... end value -1
Writing hysteresis
0 ... 255
Writing pulse duration*
0 ... 510ms
Single/periodic count, main count direction down:
Job
Valid range
Writing counter directly
2 ... +2147483647 (2
31
-1)
Writing the load value
2 ... +2147483647 (2
31
-1)
Writing comparison value
1 ... +2147483647 (2
31
-1)
Permitted value range
for JOB_VAL
VIPA System 300S
Deployment I/O periphery
Counter > SFB 47 - COUNT - Counter controlling
HB140 | CPU-SC | 312-5BE13 | GB | 15-50