Thick-ethernet-cable networks
CP1413plus manual
2-12
Rev. 00/07
Guidelines for the routing and installation of network components:
•
As a rule, a minimum distance of 1m is prescribed with respect to electrical equipment, cabling
and other components that could produce electromagnetic and electrostatic fields. This includes
parallel runs of power or high-tension cables, circuit breakers etc.
•
The ISO-specifications allow for a maximum field strength of 2 V/m at frequencies between 10
kHz and 30 MHz and 5 V/m at frequencies between 30 MHz and 1 GHz.
•
Once a coaxial cable segment and all its components have been installed it is essential that the
worst-case reflections on the cable are determined. These should never exceed 7% of the injected
amplitude of the original signal. The reflection coefficient can be checked by means of a
reflectometer.
•
The overall loop resistance of a coaxial cable segment together with all its plugs and connectors
may not exceed a maximum of 5
Ω
.
•
The minimum radius of any bend in the cable may not be less than 21 cm. Where multiple bends
are anticipated the radius must not be less than 40 cm.
Summary of Contents for CP 1413plus
Page 2: ...jkjlj...
Page 8: ...Contents CP1413plus manual iv Rev 00 07...
Page 10: ......
Page 16: ...Special features CP1413plus manual 1 6 Rev 00 07...
Page 18: ......
Page 38: ...Standards and specifications CP1413plus manual 2 20 Rev 00 07...
Page 40: ......
Page 104: ...Entry into protocol file H1PROT_NIF CP1413plus manual 3 64 Rev 00 07...
Page 106: ......
Page 178: ...PLC Layer 7 program interface CP1413plus manual 4 72 Rev 00 07...
Page 180: ......
Page 194: ......
Page 206: ...ksdjfk...
Page 306: ......
Page 317: ...Appendix A Technical data A 1 B Abbreviations B 1 C List of figures C 1 D Index D 1...
Page 318: ...dfgdfgfdg...
Page 324: ...List of figures CP1413plus manual C 2 Rev 00 07...