The Door Station has a dry contact relay. Depending on which door strike you have, will depend on how you
wire the door strike, whether it be wired to the Normally Open or Normally Closed contact.
When connecting the Door Station to an Electric Door
Strike:
• The Electric Door Strike positive (+) is connected to
the 12V DC power supply positive (+).
• The Electric Door Strike negative (-) is connected
Door Stations COM terminal.
• The 12V DC power supply negative (-) is connected to
the Door Stations NO or NC terminal depending on
the model of door strike.
3.5
Wiring an Electric Door Strike to the Door Station
Normally Closed Door Strike Wiring
Normally Open Door Strike Wiring
Unlock Button Wiring
If you wish to wire in an external button to trigger the
door latch, connect the button to the terminal marked
“Unlock Button” and “GND”.
Please note that the below diagrams reference the
INTIPRDSVW
, the
INTIPRDSB
and
INTIPRDSBW
are