4 – 20
Press the
(PAUSE) key to cancel PAUSE mode.
There may be instances when the registration-mark sensor does not function correctly, depending on how
it is moved. If this happens, adjusting the sensitivity will enable the sensor to perform detection correctly in
most cases.
Press the
(PAUSE) key to switch to PAUSE mode.
Press the
(NEXT) or
(PREV.) key until the following menu is displayed.
Press the
(ENTER) key to display the Auto Reg. Mark submenu, and then press the
(NEXT) or
(PREV.) key until the following menu is displayed.
Press the
(ENTER) key to display the Mark Sensor sensitivity setting.
Use the
or
key to increase or decrease the setting within the range of “-5” to “5,” and then press the
(ENTER) key to confirm. A positive value increases the sensitivity, but makes the cutting plotter more
susceptible to other influences and less able to withstand noise. A negative value decreases the sensitivity,
but makes the cutting plotter less susceptible to other influences and more able to withstand noise. To can-
cel the selection, press the
(NEXT) or
(PREV.) key.
Press the
(PAUSE) key to cancel PAUSE mode.
Step
6
Adjusting the Sensitivity of the Registration-Mark Sensor
Step
1
Step
2
Step
3
Step
4
Step
5
Step
6
A U T O R E G . M A R K
M A R K S E N S O R A D J
M A R K S E N S O R 0
Summary of Contents for Qe60
Page 1: ...Vinyl Express Qe60 USER S MANUAL MANUAL NO VEXQe06 UM 151 CUTTING PLOTTER Signwarehouse com ...
Page 2: ......
Page 6: ...iv ...
Page 28: ...2 14 ...
Page 42: ...3 14 ...
Page 94: ...4 52 ...
Page 100: ...5 6 ...
Page 110: ...A 4 Appendix C External Dimensions Units mm Dimensional accuracy 5 mm 851 585 1004 ...
Page 112: ...A 6 ...