4 – 14
Press the
(ENTER) key to display the registration-mark size setting.
Use the
or
key to set the value within the range “5 mm” to “20 mm,” and then press the
(ENTER) key to confirm. To cancel the selection, press the
(NEXT) or
(PREV.) key.
Press the
(PAUSE) key to cancel PAUSE mode.
This adjusts the distance between registration marks automatically, rounding up or down to the nearest 5
mm, 10 mm, or 50 mm as specified. If STD. (Standard) is selected, the distance is automatically rounded
up or down to the nearest 5 mm, 10 mm, or 50 mm depending on the distance between the marks.
Up to 50 cm: 5 mm; 50 cm to 1 m: 10 mm; 1 m or larger: 50 mm. (Inch display: rounded up or down to the
nearest 0.25", 0.5", 0.75", 1", or 1.5").
For example, if the distance adjustment is set to 5 mm and the distance between the registration marks is
read as 312 mm, the distance is rounded down to the nearest 5 mm and is treated as a distance of 310
mm.
Press the
(PAUSE) key to switch to PAUSE mode.
Press the
(NEXT) or
(PREV.) key until the following menu is displayed.
Press the
(ENTER) key to display the Auto Reg. Mark submenu, and then press the
(NEXT) or
(PREV.) key until the following menu is displayed.
Press the
(ENTER) key to display the registration-mark distance-adjustment setting.
Step
4
Step
5
Step
6
Setting the Registration-mark Distance Adjustment
Step
1
Step
2
Step
3
Step
4
M A R K S I Z E 1 0 m m
A U T O R E G . M A R K
M A R K D I S T . A D J .
M A R K D I S T . O F F
Summary of Contents for Qe60
Page 1: ...Vinyl Express Qe60 USER S MANUAL MANUAL NO VEXQe06 UM 151 CUTTING PLOTTER Signwarehouse com ...
Page 2: ......
Page 6: ...iv ...
Page 28: ...2 14 ...
Page 42: ...3 14 ...
Page 94: ...4 52 ...
Page 100: ...5 6 ...
Page 110: ...A 4 Appendix C External Dimensions Units mm Dimensional accuracy 5 mm 851 585 1004 ...
Page 112: ...A 6 ...