Document: 1795en03.doc
WESTERSTRAND
Author: PM
Date: May 8, 2014
Page: 5 of 11
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Status IP
Work mode
S = Server. The Master Clock works as a NTP time server.
C = Client. The Master Clock works as a NTP time client.
Link indicator
L = Link activated. The Master Clocks is connected to a network.
= No link activated. The Master Clock is not connected to a network.
Activity indicator A = Showing the network traffic from / to the Master Clock.
Work mode (NTP Server or Client)
The network module kan work in two different modes
Server:
The Master Clock works as a NTP time server answering to NTP requests from NTP clients.
Client/Server:
The Master Clock is both NTP client and NTP server.
The work mode is set from the Master Clock, SPEC.-FUNKTIONS / SETUP / SYNC.SOURCE.
SYNC.SOURCE = NTP CLIENT
The Master Clock acts as a NTP-client receiving its time from an external NTP server.
SYNC.SOURCE = NMEA, GPS, etc.;
The Master Clock acts as a NTP server providing connected external clients with correct time.
S L A
192.168.1.10
Present IP-address
Work mode
Link- indicator
Activity indicator