MARINE MASTER CLOCK
Document: 1717en19.doc
Author: PM
User Manual
Date: 2017-12-22
Page: 34 of 51
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Setup sync. source
Below is a description of the different configuration parameters available in the setup menu for
sync. source
.
Please remark that if default settings are used no configuration is needed.
Type of synchronisation
State type of external synchronisation. The following time sources can be selected:
NMEA RS485 (default)
Synchronisation using RS485 input and NMEA ZDA protocol.
NMEA RS232
Synchronisation using RS232 input and NMEA ZDA protocol.
W-GPS
Radio synchronisation GPS type Westerstrand.
DCF77
Radio synchronisation DCF77.
TC
Time code type hard wired DC
--------
No external synchronisation
.
Alarm limit
The configuration parameter
Alarm limit
specifies the time delay before the radio alarm is activated. Default
setting is that the radio alarm is inactivated, AL.LIMIT --h--m.
NMEA RS485
AL. LIMIT --h--m
Type of synchronisation
Alarm limit