MARINE MASTER CLOCK
Document: 1717en19.doc
Author: PM
User Manual
Date: 2017-12-22
Page: 24 of 51
WESTERSTRAND URFABRIK AB
P.O. Box 133
Tel. +46 506 48000
Internet:: http://www.westerstrand.se
SE-545 23 TÖREBODA
Fax. +46 506 48051
E-mail:
Week Program, example 6 (Mask program)
Example: Outputs No. 2 shall switch on for 5 seconds every hour at minute 15, all days in the week.
Select function using
↑↓
.
Enter programming mode using YES.
Select new program using YES.
Select group of programs using
↑↓
, accept using YES.
Select output using
↑↓
. Move to the right using
→
.
State type of signal using
↑↓
.
05S = Pulse with 5 seconds length.
State the days the program shall function using
↑↓
.
Move to the right using
→
.
State the time of the program using
↑↓
. ** = every hour.
Move to the right using
→
.
Accept using YES.
If the program is approved the text “Program saved” is displayed quickly.
Leave programming by pressing
←
several times.
MON 26 SEP 2016
U10:11:00 L12:11
WEEK PROGRAM
WEEK PROGRAM
NEW
GROUP A
OUTPUT 2
ON
------- 08:00:00
OUTPUT 2 05S
MTWTFSS
08:00:00
WEEK PROGRAM
NEW
GROUP A
OUTPUT 2
05S
------- 08:00:00
OUTPUT 2 05S
MTWTFSS **
:15:00
WEEK PROGRAM
MON 26 SEP 2016
U10:11:00 L12:11
Summary of Contents for 3005050028
Page 1: ...TECHNICAL MANUAL MASTER CLOCK SYSTEM TECHNICAL USER MANUAL A100K10807 ...
Page 76: ......