Impulse length
Configuration of impulse length.
1/1 and 1/2 -minute impulse:
0.1s – 9.9 s.
Second impulses:
0.1 – 1.0 s.
Alarm limits
Impulse current low limit
Alarm limit for low current (minimum load). The minimum load can be set from 0A up to 2.0A.
Impulse current high limit
Alarm limit for high current (maximum load). The maximum load can be set from 0A up to 2.0A.
Impulse feedback voltage limit
Alarm limit for feedback impulse voltage.
--
: No limit (default).
01 - 99
: Limit in volts, V.
IL=0.0 - 2.0A
UF= -- V
Impulse current high limit
Impulse current low limit
Impulse feedback
voltage limit