background image

33

EN

V7

N

DEF 

V8

O

GHI 

V9

P

JKL 

V10

Q

MNO 

V11

R

PQRS 

V12

S

TUV 

V13

T

WXYZ 

V14

U

Note:

 In the case of Horizontal installation, the prefix 

H

 indicates a Horizontal electronic unit, while 

V

 indicates one of 

the vertical electronic units of the riser where there is the indoor unit. V15 does not exist, its function is performed by the 

69RS. Cyclic self-starting is possible only on the first 16 horizontal electronic units. For the others, direct self-starting 

is possible, after suitably programming the 69RS.

After the first 

, or second 

 or 

 button, a symbol will appear indicating that another number key is expected.

A “clipboard” function can be used to help with duplication of the codes. When no symbol is shown as described above, 

press 

 to record the sequence shown on the display. Select another device, access changes mode and press 

 

to replace the existing sequence with the sequence recorded in the clipboard. Press 

 to confirm the change. 

Note

: Each horizontal electronic unit can function as a Master (as regards self-starting) for the indoor units whose ID is 

within the Initial ID - Final ID range (paragraph 1.3 and 1.4). It is enough for 69RS to have the Master entrance panel 

of the riser remapped onto the current entrance panel.

Default: no sequence, so only the Master entrance panel (Vertical Installation) or the current one (Horizontal 

Installation) is considered.

4.10 - DATE / TIME format

While awaiting selection, the electronic unit shows, among other information, the current date and time. The formats 

in which they are shown are configurable. If desired, you can also delete one or both of them. Enter changes mode 

with 

, select the desired format with 

 or 

, confirm with 

. The time format is reached with 

 starting 

from the date format.

Default: display date in the format day month / numeric month / 4-digit year, hour and minutes in 24H format 

separated by ':', 01/01/2013 00:00:00.

5.0 - Clock

The clock must be set correctly for the service described in paragraphs 5.1 to 5.4 to be able to be correctly performed. 

The date and time are retained for at least 2 days even with the electronic unit switched off. When the clock is first 

powered up, or when the electronic unit remains switched off for longer than 2 days, the date is automatically set to 1 
January 2013 and the time to 00:00. To adjust the date and time, press 

. The modifiable field is indicated by a solid 

rectangle to the right. To change the data for the day, enter numbers 

 .. 

WXYZ 

 with the keypad and to move on to 

another field, use the 

 button to move right and 

 to move left. Confirm with 

. If there is an error, for example 

if the day is set any higher than 31, changes are rejected and the rectangle moves to the position of the error. There 

is no need to enter the day of the week, as this will be calculated automatically from the date.

5.1 - Enable timed codes

This configuration enables the timed password function described under headings 5.2, 5.3 and 5.4. To enable press 

. To disable press 

.

Default: No

5.2 - First timed code

This configuration specifies the first code to be used for the Timed Codes function. Using buttons from 

 

to 

WXYZ 

 

enter its number from 1 to 1000 or 

 to delete it. If the first code is higher than the second, or if one is programmed 

and the other is not, a warning to check the other code is displayed. The valid codes are those in which the number 

ranges from the first to the last as specified, excluding the limits.

Default: not programmed

5.3 - Last timed code

Like the code described above, but referring to the last valid code. 

Default: not programmed

 

5.0

Clock

4.10

Date / Time format

5.1

Enabled time codes

5.2

First Call Time

5.3

Last call Time

Summary of Contents for ELVOX 13F4

Page 1: ...nit Due Fili colori con tastiera keypad audio Due Fili unit keypad colour Due Fili unit Manuale installatore Installer guide 3 2 1 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MNO PQRS TUV WXYZ R 3 2 1 1 2 3 4...

Page 2: ...EN 61000 6 1 EN 61000 6 3 INFORMAZIONE AGLI UTENTI AI SENSI DELLA DIRETTIVA 2002 96 RAEE Al fine di evitare danni all ambiente e alla salute umana oltre che di incorrere in sanzioni amministrative l...

Page 3: ...features electronic units that fully manage up to 1000 users each NOTE The values indicated in square brackets refer to the HORIZONTAL INSTALLATION configuration 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MN...

Page 4: ...lectronic unit To connect an external CCTV camera to an audio electronic unit 13F4 the electronic unit must be configured as if it were intended for video entryphone use This type of configuration is...

Page 5: ...set of the configurations of the electronic unit those that most determine the operating characteristics or that are necessary for other reasons PARAMETER PARAGRAPH Language 1 0 Date and Time format 4...

Page 6: ...ID 1 happens to be 51 and 51 has already been allocated the unit will be allocated the first secondary ID available Call On alphanumeric electronic units there are 4 ways of dialling a user and sendi...

Page 7: ...from entrance panel Proceed as in the previous case but the access code is R 3 DEF and is not configurable Note The procedures described above are possible only with the entrance panel at rest i e no...

Page 8: ...3 Function 1 Time 1 s 5 5 Device 3 4 Function 2 Time 1 s 5 6 Button Notes configurable only with MASTER or horizontal electronic unit only in the vertical configuration only in the horizontal configu...

Page 9: ...s the electronic unit with a code between 1 and 15 1 and 36 If the value is 1 the electronic unit is set as MASTER if the value is between 2 and 15 2 and 36 the electronic unit is set as SLAVE Enter t...

Page 10: ...Default 0 no remapping Note If the settings of paragraphs 1 5 and 1 6 are simultaneously present Button Remapping takes priority 1 7 Single buttons If you use modules Art 12TS activate mode 1 Single b...

Page 11: ...um breadth of the ID range in the case of Horizontal installation There are always 1000 passwords also in the case of Vertical installation The activation time is set with LOCK TIME paragraph 3 2 The...

Page 12: ...e buttons or key in the number to select one of the 200 1000 users Each user is matched with two names a and b to be selected with buttons Having located the required line press the button to change t...

Page 13: ...ess to confirm the change Default 1 s minimum value 0 s corresponding to lock always off maximum value 255 s 3 3 Function 1 time Activation time of the device connected between terminals 12V F1 Enter...

Page 14: ...s i e activated at the same time as others for example the lock release of a different electronic unit see lock F1 F2 Common paragraphs 4 4 4 5 4 6 Use buttons and or the numeric keypad to select the...

Page 15: ...r units you can choose a traditional button that makes a direct call to it Use the and buttons to choose the number of the consumer unit Then key in the number of the button or 0 to cancel the program...

Page 16: ...cyclical start up of a sequence of electronic units can be associated with the self start button of each indoor unit Use the and buttons or the numerical keypad to select one of the 200 1000 physical...

Page 17: ...th starting from the date format Default display date in the format day month numeric month 4 digit year hour and minutes in 24H format separated by 01 01 2013 00 00 00 5 0 Clock The clock must be set...

Page 18: ...9 WXYZ to set the time only If need be buttons and can be used to set the minutes Default not programmed 5 5 Change indoor unit configurations This function is only available for Vertical Installation...

Page 19: ...L P P P C C C Schema di collegamento di pi unit elettroniche audio Wiring diagram for multiple audio electronic units C Unit elettronica audio o video F Alimentatore di sistema L Serratura elettrica...

Page 20: ...apriporta X Cavo twistato G Alimentatore supplementare alimentazione unit elettronica C Unit elettronica audio F Alimentatore di sistema L Serratura elettrica 12 Vdc M1 Telecamera esterna tipo TVCC 12...

Page 21: ...rsion Unit elettronica con cartello numero civico retroilluminato Electronic unit with backlit house number plate module Circuito di illuminazione Art 805N e 80PN Lighting circuit Art 805N and 80PN Ut...

Page 22: ...mento VLED 12 Connection VLED 12 Variante Version Collegamento per segnalazione Porta Cancello aperto Wiring for Door Gate open indication C D Unit elettronica audio o video L Serratura elettrica 12 V...

Page 23: ...ection of auxiliary functions F1 and F2 D Unit elettronica L Serratura elettrica 12 Vdc Q Rel Art 0170 001 Variante Version Schema di collegamento serratura con alimentazione supplementare Connection...

Page 24: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400632A0 02 1405 VIMAR Marostica Italy...

Reviews: