background image

32

EN

 4.5 - F1 common 

As for the lock, but for the output F1.

                                            

4.6 - F2 common 

As for the lock, but for the output F2.

4.7 - Disable slave panel search

This parameter is only present if the entrance panel is the Master or is configured for Horizontal Installation. It can be 

used to disable the search for Slave electronic units via the Master electronic unit, on start-up or after pressing the 
RESET button. Press 

 to deactivate the search, and 

 to activate the search. Press 

 to confirm the change. 

Default = Yes

4.8 - Self-start disabling

This parameter is only present if the entrance panel is the Master or is configured for Horizontal Installation. It inhibits 
self-starting from all the system's indoor units. Press 

 to deactivate self-start, and 

 to activate self-start. Press 

 to confirm the change.

Default = No

4.9 - Self-start sequence

 

This parameter is only present if the entrance panel is the Master or is configured for Horizontal Installation. With 

this parameter, the cyclical start-up of a sequence of electronic units can be associated with the self-start button of 

each indoor unit. Use the 

 and 

 buttons or the numerical keypad to select one of the 200 [1000] physical codes 

(device ID) corresponding to an indoor unit.

Note:

 You can use the codes from 201 to 204 [from INITIAL ID + 1000 to INITIAL ID + 1007, from 1001 to 1008 by 

default], for the concierge switchboards, but with the current FW the self-start function is not performed.

Having located the required code, press the 

 button to change the value. The 

 button deletes the last electronic 

unit in the sequence. To enter the numbers of the electronic units, proceed as indicated in the following table:

Vertical installation

Horizontal 

installation

Number / Letter

First

Button

Second

Button

Third

Button

1

H1

1

2

H2

2

ABC 

3

H3

3

DEF 

4

H4

4

GHI 

5

H5

5

JKL 

6

H6

6

MNO 

7

H7

7

PQRS 

8

H8

8

TUV 

9

H9

9

WXYZ 

10

H10

A

11

H11

B

12

H12

C

ABC 

13

H13

D

DEF 

14

H14

E

GHI 

15

H15

F

JKL 

H16

G

MNO 

V1

H

PQRS 

V2

I

TUV 

V3

J

WXYZ 

V4

K

V5

L

V6

M

ABC 

4.6

F2 common

4.7

Disable SB search

4.5

F1 common

4.8

Disable S.start

4.9

Seq. Self-start

Summary of Contents for ELVOX 13F4

Page 1: ...nit Due Fili colori con tastiera keypad audio Due Fili unit keypad colour Due Fili unit Manuale installatore Installer guide 3 2 1 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MNO PQRS TUV WXYZ R 3 2 1 1 2 3 4...

Page 2: ...EN 61000 6 1 EN 61000 6 3 INFORMAZIONE AGLI UTENTI AI SENSI DELLA DIRETTIVA 2002 96 RAEE Al fine di evitare danni all ambiente e alla salute umana oltre che di incorrere in sanzioni amministrative l...

Page 3: ...features electronic units that fully manage up to 1000 users each NOTE The values indicated in square brackets refer to the HORIZONTAL INSTALLATION configuration 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MN...

Page 4: ...lectronic unit To connect an external CCTV camera to an audio electronic unit 13F4 the electronic unit must be configured as if it were intended for video entryphone use This type of configuration is...

Page 5: ...set of the configurations of the electronic unit those that most determine the operating characteristics or that are necessary for other reasons PARAMETER PARAGRAPH Language 1 0 Date and Time format 4...

Page 6: ...ID 1 happens to be 51 and 51 has already been allocated the unit will be allocated the first secondary ID available Call On alphanumeric electronic units there are 4 ways of dialling a user and sendi...

Page 7: ...from entrance panel Proceed as in the previous case but the access code is R 3 DEF and is not configurable Note The procedures described above are possible only with the entrance panel at rest i e no...

Page 8: ...3 Function 1 Time 1 s 5 5 Device 3 4 Function 2 Time 1 s 5 6 Button Notes configurable only with MASTER or horizontal electronic unit only in the vertical configuration only in the horizontal configu...

Page 9: ...s the electronic unit with a code between 1 and 15 1 and 36 If the value is 1 the electronic unit is set as MASTER if the value is between 2 and 15 2 and 36 the electronic unit is set as SLAVE Enter t...

Page 10: ...Default 0 no remapping Note If the settings of paragraphs 1 5 and 1 6 are simultaneously present Button Remapping takes priority 1 7 Single buttons If you use modules Art 12TS activate mode 1 Single b...

Page 11: ...um breadth of the ID range in the case of Horizontal installation There are always 1000 passwords also in the case of Vertical installation The activation time is set with LOCK TIME paragraph 3 2 The...

Page 12: ...e buttons or key in the number to select one of the 200 1000 users Each user is matched with two names a and b to be selected with buttons Having located the required line press the button to change t...

Page 13: ...ess to confirm the change Default 1 s minimum value 0 s corresponding to lock always off maximum value 255 s 3 3 Function 1 time Activation time of the device connected between terminals 12V F1 Enter...

Page 14: ...s i e activated at the same time as others for example the lock release of a different electronic unit see lock F1 F2 Common paragraphs 4 4 4 5 4 6 Use buttons and or the numeric keypad to select the...

Page 15: ...r units you can choose a traditional button that makes a direct call to it Use the and buttons to choose the number of the consumer unit Then key in the number of the button or 0 to cancel the program...

Page 16: ...cyclical start up of a sequence of electronic units can be associated with the self start button of each indoor unit Use the and buttons or the numerical keypad to select one of the 200 1000 physical...

Page 17: ...th starting from the date format Default display date in the format day month numeric month 4 digit year hour and minutes in 24H format separated by 01 01 2013 00 00 00 5 0 Clock The clock must be set...

Page 18: ...9 WXYZ to set the time only If need be buttons and can be used to set the minutes Default not programmed 5 5 Change indoor unit configurations This function is only available for Vertical Installation...

Page 19: ...L P P P C C C Schema di collegamento di pi unit elettroniche audio Wiring diagram for multiple audio electronic units C Unit elettronica audio o video F Alimentatore di sistema L Serratura elettrica...

Page 20: ...apriporta X Cavo twistato G Alimentatore supplementare alimentazione unit elettronica C Unit elettronica audio F Alimentatore di sistema L Serratura elettrica 12 Vdc M1 Telecamera esterna tipo TVCC 12...

Page 21: ...rsion Unit elettronica con cartello numero civico retroilluminato Electronic unit with backlit house number plate module Circuito di illuminazione Art 805N e 80PN Lighting circuit Art 805N and 80PN Ut...

Page 22: ...mento VLED 12 Connection VLED 12 Variante Version Collegamento per segnalazione Porta Cancello aperto Wiring for Door Gate open indication C D Unit elettronica audio o video L Serratura elettrica 12 V...

Page 23: ...ection of auxiliary functions F1 and F2 D Unit elettronica L Serratura elettrica 12 Vdc Q Rel Art 0170 001 Variante Version Schema di collegamento serratura con alimentazione supplementare Connection...

Page 24: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400632A0 02 1405 VIMAR Marostica Italy...

Reviews: