background image

22

EN

-  There can be three cases:

ID already exists

Unique ID already assigned

Unique ID not assigned

The procedure applies both to the main ID and to a secondary one. In 

the latter case, the ID to be entered is that of the main one (or master) to 

which you want to link the indoor unit being assigned the ID. The range 

of available values   in this case is limited to 1..50 since the electronic unit 

automatically calculates the secondary ID to be associated with it and finds 

one that is available. If you enter an ID greater than 50:

-  Repeat the procedure for all indoor units.

During programming, a timeout of 25 seconds is available in which to allo-

cate the code to a device, otherwise the electronic unit automatically exits 

the procedure.

Note:

 The ID can only be assigned if the configuration in paragraph 1.8 is 

set to

 Sequential

Automatic ID assignment

1) Type in 

 + 

MNO 

2) Enter the current password (default 

MNO 

 

JKL 

 

GHI 

 

DEF 

 

ABC 

 

), confirm 

with 

.

3) Indicate the ID number from which to start the allocation process.

4) Run the ID assignment procedure for the indoor unit within 5 minutes (for 

the procedure please refer to the product's instructions). 

5) The electronic unit communicates with the indoor unit being programmed 

and assigns the ID chosen in point 3).

6) The electronic unit automatically makes a call to the indoor unit that has 

just been encoded. You can answer or let it end.

7) Repeat the procedure from step 4) onwards, to complete the automatic 

ID number allocation for other devices. The new ID will be increased by 1.

Note

: the timeout setting is approximately 5 minutes, renewable at the end 

of each operation.

Note

: the programming will lock up if there is an indoor unit in the system 

already having an associated ID number located internally of the allocation 

window. For example, if ID = 5 is typed into the electronic unit and there are 

indoor units that have already been allocated an ID number lower than 5, 

there will be no problem running the automatic procedure. Should there be 

an indoor unit in the system that has previously been allocated the number 

ID = 9, the programming function will allocate 5, 6, 7, 8, and then lock up, 

due to the fact that 9 already exists and therefore cannot be allocated.  

To continue with automatic allocation, the user must correct the sequence 

manually, in this instance at step 3) of the procedure, by entering the num-

ber ID = 10.

Note

: The maximum number of secondary IDs for each primary ID that can 

be configured with the procedure described here is 3. 

IMPORTANT

: First 

encode the secondary IDs, then the relevant master.

Note

: In the event that a secondary ID number is already in use (for ex-

ample the first secondary number of ID = 1 happens to be 51 and 51 has 

already been allocated, the unit will be allocated the first secondary ID 

available.

Call

On alphanumeric electronic units, there are 4 ways of dialling a user and 

sending a call:

Numeric dial.

Alphanumeric dial.

Direct dial.

Traditional buttons.

Numeric dialling

Dial the call code of the desired extension using buttons 

 to 

WXYZ 

. Press 

 to cancel the operation or 

 to call. When dialling, if 

 is active 

for selection of the “Lock code" (paragraph 1.9), do not utilize 

 as the 

first button. If the code called is associated with a name in the contacts list, 

the first associated name (a) will be displayed while the call is being made.

Note

: The concierge switchboards are associated with the numbering from 

201 (40001) onwards. For ease of use you can select them directly with 

buttons 

 and 

 (paragraphs 2.0 and 2.1) or the traditional buttons, 

configuring them as described in section 4.2.

Alphanumeric selection (if there is at least one name in the 

contacts list)

Press button 

.

 

Enter all or the first few letters of the name to be found.

 

To 

enter characters/symbols, use buttons 

 to 

WXYZ 

. Each button has more 

than one character/symbol associated with it (see table 3).

Button

Symbol

(IT-EN-FR-DE-ES-PT)

Symbol

(EL)

<space>1@.,:;?!()<>

Space 1@.,:;?!()<>

ABC 

ABC2abcÁÀ

Ă

ÃÅÄÆÇ

ČĆ

áà

ă

ãåäæç

č

ΑΒΓ2ΆABCabc

DEF 

DEF3defÉÈÊ

ĚĘď

éèê

ě

ΔΕΖ3ΈDEFdef

GHI 

GHI4ghiÍÌíì

ΗΘΙ4ΉΊΪGHIghi

JKL 

JKL5jkl

Ł

ΚΛΜ5JKLjkl

MNO 

MNO6mnoÑñÓÒ

Ŏ

ÕÖØóò

ŏ

õöø

ΝΞΟ6ΌMNOmno

PQRS 

PQRS7pqrs

Ř

Š

řšßŚ

ΠΡΣ7PQRSpqrs

TUV 

TUV8tuvÚÙÜ

Ů

úùü

ů

ΤΥΦ8ΎΫTUVtuv

WXYZ 

WXYZ9wxyzÝ

ŽŹŻ

ý

ž

ΧΨΩ9ΏWXYZwxyz

0_$&*#+-=/%”’

0_$&*#+-=/%“‘

Table 3

To find the desired symbol, press the button repeatedly before the end of 

the 2 s timeout, which is renewed with each press of the button. 

If the symbol entered previously was an upper case character, even if the 

button is changed, the function will restart with upper case. If the symbol 

was lower case, the function will restart with lower case. If the symbol was 
a digit, the function will restart with a digit. To enter a character

 

/

 

symbol 

located on a different button from the one previously pressed, it is not nec-

essary to wait for the end of the timeout.

Use the 

 and 

 buttons to start the name search. 

If the name entered forms part of the name being searched for, the elec-

tronic unit will display the first name that meets the search criteria; use the 

 and 

 buttons to scroll back and forth through the list.

Having found the name, press the 

 button to send a call. Press the 

 

button to cancel the operation.

Direct dialling

Pressing one of the two 

 

 buttons, a call can be made directly to 

two different numbers. This is possible only if the two buttons have been 
encoded as described in paragraphs 2.0 and 2.1. 

Traditional buttons

Up to two 12TS button modules or one 12TD button module can be con-

nected for calls directed to a specific user. The associated buttons are sub-

ject to the configurations described in paragraphs 1.5, 1.6, 1.7, 4.2 and 4.3.

Note:

 In whatever way a call has been started, you can cancel it by pres-

Summary of Contents for ELVOX 13F4

Page 1: ...nit Due Fili colori con tastiera keypad audio Due Fili unit keypad colour Due Fili unit Manuale installatore Installer guide 3 2 1 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MNO PQRS TUV WXYZ R 3 2 1 1 2 3 4...

Page 2: ...EN 61000 6 1 EN 61000 6 3 INFORMAZIONE AGLI UTENTI AI SENSI DELLA DIRETTIVA 2002 96 RAEE Al fine di evitare danni all ambiente e alla salute umana oltre che di incorrere in sanzioni amministrative l...

Page 3: ...features electronic units that fully manage up to 1000 users each NOTE The values indicated in square brackets refer to the HORIZONTAL INSTALLATION configuration 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MN...

Page 4: ...lectronic unit To connect an external CCTV camera to an audio electronic unit 13F4 the electronic unit must be configured as if it were intended for video entryphone use This type of configuration is...

Page 5: ...set of the configurations of the electronic unit those that most determine the operating characteristics or that are necessary for other reasons PARAMETER PARAGRAPH Language 1 0 Date and Time format 4...

Page 6: ...ID 1 happens to be 51 and 51 has already been allocated the unit will be allocated the first secondary ID available Call On alphanumeric electronic units there are 4 ways of dialling a user and sendi...

Page 7: ...from entrance panel Proceed as in the previous case but the access code is R 3 DEF and is not configurable Note The procedures described above are possible only with the entrance panel at rest i e no...

Page 8: ...3 Function 1 Time 1 s 5 5 Device 3 4 Function 2 Time 1 s 5 6 Button Notes configurable only with MASTER or horizontal electronic unit only in the vertical configuration only in the horizontal configu...

Page 9: ...s the electronic unit with a code between 1 and 15 1 and 36 If the value is 1 the electronic unit is set as MASTER if the value is between 2 and 15 2 and 36 the electronic unit is set as SLAVE Enter t...

Page 10: ...Default 0 no remapping Note If the settings of paragraphs 1 5 and 1 6 are simultaneously present Button Remapping takes priority 1 7 Single buttons If you use modules Art 12TS activate mode 1 Single b...

Page 11: ...um breadth of the ID range in the case of Horizontal installation There are always 1000 passwords also in the case of Vertical installation The activation time is set with LOCK TIME paragraph 3 2 The...

Page 12: ...e buttons or key in the number to select one of the 200 1000 users Each user is matched with two names a and b to be selected with buttons Having located the required line press the button to change t...

Page 13: ...ess to confirm the change Default 1 s minimum value 0 s corresponding to lock always off maximum value 255 s 3 3 Function 1 time Activation time of the device connected between terminals 12V F1 Enter...

Page 14: ...s i e activated at the same time as others for example the lock release of a different electronic unit see lock F1 F2 Common paragraphs 4 4 4 5 4 6 Use buttons and or the numeric keypad to select the...

Page 15: ...r units you can choose a traditional button that makes a direct call to it Use the and buttons to choose the number of the consumer unit Then key in the number of the button or 0 to cancel the program...

Page 16: ...cyclical start up of a sequence of electronic units can be associated with the self start button of each indoor unit Use the and buttons or the numerical keypad to select one of the 200 1000 physical...

Page 17: ...th starting from the date format Default display date in the format day month numeric month 4 digit year hour and minutes in 24H format separated by 01 01 2013 00 00 00 5 0 Clock The clock must be set...

Page 18: ...9 WXYZ to set the time only If need be buttons and can be used to set the minutes Default not programmed 5 5 Change indoor unit configurations This function is only available for Vertical Installation...

Page 19: ...L P P P C C C Schema di collegamento di pi unit elettroniche audio Wiring diagram for multiple audio electronic units C Unit elettronica audio o video F Alimentatore di sistema L Serratura elettrica...

Page 20: ...apriporta X Cavo twistato G Alimentatore supplementare alimentazione unit elettronica C Unit elettronica audio F Alimentatore di sistema L Serratura elettrica 12 Vdc M1 Telecamera esterna tipo TVCC 12...

Page 21: ...rsion Unit elettronica con cartello numero civico retroilluminato Electronic unit with backlit house number plate module Circuito di illuminazione Art 805N e 80PN Lighting circuit Art 805N and 80PN Ut...

Page 22: ...mento VLED 12 Connection VLED 12 Variante Version Collegamento per segnalazione Porta Cancello aperto Wiring for Door Gate open indication C D Unit elettronica audio o video L Serratura elettrica 12 V...

Page 23: ...ection of auxiliary functions F1 and F2 D Unit elettronica L Serratura elettrica 12 Vdc Q Rel Art 0170 001 Variante Version Schema di collegamento serratura con alimentazione supplementare Connection...

Page 24: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400632A0 02 1405 VIMAR Marostica Italy...

Reviews: