background image

25

EN

The following sections describe the possible configurations of the electronic units using the keypad and display. For 

all of them, to confirm the change in configuration, the first line of the display shows:

In the event of parameter error, the display shows a situation similar to this:

You can go to the next setting by pressing the 

 button, to the previous one with 

. Exceptions are those settings 

that regard the indoor units (for example, the contacts list) or that refer to a number of sub-configurations (for exam-

ple, time slots). For these, with 

 you go to the indoor unit or to the next sub-configuration, to reach the end of the 

previous setting. With the 

 button you skip straight to the previous setting.  Settings that behave in this way are 

highlighted by the 

 symbol next to the title.

The 

 button is used to cancel the change in progress or to return the electronic unit to rest if there are no pending 

changes.

1.0 - Message language

Indicates the language used for displaying messages both during normal use (

user

 messages) and for the config-

uration of the electronic unit (

technical

 messages). To change the set language, press the number on the keypad 

corresponding to the required language as indicated in the table or use the arrow keys.

BUTTON

ABC 

DEF 

GHI 

JKL 

MNO 

LANGUAGE

Italian

English

French

German

Spanish

Portuguese

Greek

Press 

 to confirm the change. The confirmation message will be displayed in the new language.

Default: Italian

1.1 - Entrance panel ID

Identifies the electronic unit with a code between 1 and 15 [1 and 36]. If the value is 1, the electronic unit is set as 

MASTER

, if the value is between 2 and 15 [2 and 36], the electronic unit is set as 

SLAVE

Enter the identification code using buttons 

 to 

WXYZ 

. Press 

 to confirm the change. Confirming the change, the 

electronic unit checks the availability of the code. If there is another electronic unit connected with the same code in 

the system, the display will show a message such as this:

and it is necessary to enter another code.
Pressing 0 will “

disable

” the electronic unit temporarily.

Default: 1

Note:

 Do not use ID 15 in the case of a downstream Vertical installation of a 69RS.

1.2 -

 

Installation

You choose the installation mode for the electronic unit: 

 for Vertical Installation or 

 for Horizontal Installa-

tion.

Default: Vertical

Note:

 Exiting the configuration and returning the electronic unit to rest forces sorting the contacts list.

Note:

 When going from Horizontal to Vertical installation congruence with other existing settings is checked. If there 

are any of them that in the Vertical configuration are no longer valid, the electronic unit will show this with a message 

regardless of the language and with a numerical code:

To confirm the move from Horizontal to Vertical, that in this case involves automatic deletion of incompatible settings, 

depress the 

 button. With 

 you cancel the procedure, leaving the electronic unit in Horizontal mode and without 

losing the settings.

1.3 -

 

Initial ID

This item appears only if the Horizontal configuration has been selected in step 1.2. It is necessary to indicate the first 

1.0

Message language

1.1

Entrance panel ID

1.2

Installation

1.3

Initial ID

Summary of Contents for ELVOX 13F4

Page 1: ...nit Due Fili colori con tastiera keypad audio Due Fili unit keypad colour Due Fili unit Manuale installatore Installer guide 3 2 1 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MNO PQRS TUV WXYZ R 3 2 1 1 2 3 4...

Page 2: ...EN 61000 6 1 EN 61000 6 3 INFORMAZIONE AGLI UTENTI AI SENSI DELLA DIRETTIVA 2002 96 RAEE Al fine di evitare danni all ambiente e alla salute umana oltre che di incorrere in sanzioni amministrative l...

Page 3: ...features electronic units that fully manage up to 1000 users each NOTE The values indicated in square brackets refer to the HORIZONTAL INSTALLATION configuration 1 2 3 4 5 6 7 8 9 0 ABC DEF GHI JKL MN...

Page 4: ...lectronic unit To connect an external CCTV camera to an audio electronic unit 13F4 the electronic unit must be configured as if it were intended for video entryphone use This type of configuration is...

Page 5: ...set of the configurations of the electronic unit those that most determine the operating characteristics or that are necessary for other reasons PARAMETER PARAGRAPH Language 1 0 Date and Time format 4...

Page 6: ...ID 1 happens to be 51 and 51 has already been allocated the unit will be allocated the first secondary ID available Call On alphanumeric electronic units there are 4 ways of dialling a user and sendi...

Page 7: ...from entrance panel Proceed as in the previous case but the access code is R 3 DEF and is not configurable Note The procedures described above are possible only with the entrance panel at rest i e no...

Page 8: ...3 Function 1 Time 1 s 5 5 Device 3 4 Function 2 Time 1 s 5 6 Button Notes configurable only with MASTER or horizontal electronic unit only in the vertical configuration only in the horizontal configu...

Page 9: ...s the electronic unit with a code between 1 and 15 1 and 36 If the value is 1 the electronic unit is set as MASTER if the value is between 2 and 15 2 and 36 the electronic unit is set as SLAVE Enter t...

Page 10: ...Default 0 no remapping Note If the settings of paragraphs 1 5 and 1 6 are simultaneously present Button Remapping takes priority 1 7 Single buttons If you use modules Art 12TS activate mode 1 Single b...

Page 11: ...um breadth of the ID range in the case of Horizontal installation There are always 1000 passwords also in the case of Vertical installation The activation time is set with LOCK TIME paragraph 3 2 The...

Page 12: ...e buttons or key in the number to select one of the 200 1000 users Each user is matched with two names a and b to be selected with buttons Having located the required line press the button to change t...

Page 13: ...ess to confirm the change Default 1 s minimum value 0 s corresponding to lock always off maximum value 255 s 3 3 Function 1 time Activation time of the device connected between terminals 12V F1 Enter...

Page 14: ...s i e activated at the same time as others for example the lock release of a different electronic unit see lock F1 F2 Common paragraphs 4 4 4 5 4 6 Use buttons and or the numeric keypad to select the...

Page 15: ...r units you can choose a traditional button that makes a direct call to it Use the and buttons to choose the number of the consumer unit Then key in the number of the button or 0 to cancel the program...

Page 16: ...cyclical start up of a sequence of electronic units can be associated with the self start button of each indoor unit Use the and buttons or the numerical keypad to select one of the 200 1000 physical...

Page 17: ...th starting from the date format Default display date in the format day month numeric month 4 digit year hour and minutes in 24H format separated by 01 01 2013 00 00 00 5 0 Clock The clock must be set...

Page 18: ...9 WXYZ to set the time only If need be buttons and can be used to set the minutes Default not programmed 5 5 Change indoor unit configurations This function is only available for Vertical Installation...

Page 19: ...L P P P C C C Schema di collegamento di pi unit elettroniche audio Wiring diagram for multiple audio electronic units C Unit elettronica audio o video F Alimentatore di sistema L Serratura elettrica...

Page 20: ...apriporta X Cavo twistato G Alimentatore supplementare alimentazione unit elettronica C Unit elettronica audio F Alimentatore di sistema L Serratura elettrica 12 Vdc M1 Telecamera esterna tipo TVCC 12...

Page 21: ...rsion Unit elettronica con cartello numero civico retroilluminato Electronic unit with backlit house number plate module Circuito di illuminazione Art 805N e 80PN Lighting circuit Art 805N and 80PN Ut...

Page 22: ...mento VLED 12 Connection VLED 12 Variante Version Collegamento per segnalazione Porta Cancello aperto Wiring for Door Gate open indication C D Unit elettronica audio o video L Serratura elettrica 12 V...

Page 23: ...ection of auxiliary functions F1 and F2 D Unit elettronica L Serratura elettrica 12 Vdc Q Rel Art 0170 001 Variante Version Schema di collegamento serratura con alimentazione supplementare Connection...

Page 24: ...Vimar SpA Viale Vicenza 14 36063 Marostica VI Italy Tel 39 0424 488 600 Fax Italia 0424 488 188 Fax Export 0424 488 709 www vimar com 49400632A0 02 1405 VIMAR Marostica Italy...