25
EN
The following sections describe the possible configurations of the electronic units using the keypad and display. For
all of them, to confirm the change in configuration, the first line of the display shows:
In the event of parameter error, the display shows a situation similar to this:
You can go to the next setting by pressing the
button, to the previous one with
. Exceptions are those settings
that regard the indoor units (for example, the contacts list) or that refer to a number of sub-configurations (for exam-
ple, time slots). For these, with
you go to the indoor unit or to the next sub-configuration, to reach the end of the
previous setting. With the
R
button you skip straight to the previous setting. Settings that behave in this way are
highlighted by the
R
symbol next to the title.
The
button is used to cancel the change in progress or to return the electronic unit to rest if there are no pending
changes.
1.0 - Message language
Indicates the language used for displaying messages both during normal use (
user
messages) and for the config-
uration of the electronic unit (
technical
messages). To change the set language, press the number on the keypad
corresponding to the required language as indicated in the table or use the arrow keys.
BUTTON
0
+
1
2
ABC
3
DEF
4
GHI
5
JKL
6
MNO
LANGUAGE
Italian
English
French
German
Spanish
Portuguese
Greek
Press
to confirm the change. The confirmation message will be displayed in the new language.
Default: Italian
1.1 - Entrance panel ID
Identifies the electronic unit with a code between 1 and 15 [1 and 36]. If the value is 1, the electronic unit is set as
MASTER
, if the value is between 2 and 15 [2 and 36], the electronic unit is set as
SLAVE
.
Enter the identification code using buttons
0
+
to
9
WXYZ
. Press
to confirm the change. Confirming the change, the
electronic unit checks the availability of the code. If there is another electronic unit connected with the same code in
the system, the display will show a message such as this:
and it is necessary to enter another code.
Pressing 0 will “
disable
” the electronic unit temporarily.
Default: 1
Note:
Do not use ID 15 in the case of a downstream Vertical installation of a 69RS.
1.2 -
Installation
You choose the installation mode for the electronic unit:
0
+
for Vertical Installation or
1
for Horizontal Installa-
tion.
Default: Vertical
Note:
Exiting the configuration and returning the electronic unit to rest forces sorting the contacts list.
Note:
When going from Horizontal to Vertical installation congruence with other existing settings is checked. If there
are any of them that in the Vertical configuration are no longer valid, the electronic unit will show this with a message
regardless of the language and with a numerical code:
To confirm the move from Horizontal to Vertical, that in this case involves automatic deletion of incompatible settings,
depress the
button. With
you cancel the procedure, leaving the electronic unit in Horizontal mode and without
losing the settings.
1.3 -
Initial ID
This item appears only if the Horizontal configuration has been selected in step 1.2. It is necessary to indicate the first
1.0
Message language
1.1
Entrance panel ID
1.2
Installation
1.3
Initial ID