Door Switch Removal
Single Oven and Upper Double Oven
The Door Switch for the single oven and upper
double oven is located above the oven cavity in
the front of the component compartment. It is used
to sense when the upper oven door is open.
WARNING:
Disconnect power to oven
before servicing. Follow lockout/tagout
procedures.
CAUTION:
Some areas of the oven
interior are sharp; wear protective gloves to
avoid injury.
Condition Requirements:
Partial Access to Control Components
1.
Remove one screw from the door switch
and slide the door switch actuator out of
the guide.
2.
Pull the door switch through the access
hole.
3.
Disconnect two connectors from the door
switch.
4.
Reverse procedure for installation.