171
DE
FR
NL
IT
EN
0478 131 9937 B - EN
Divided mowing area with a pond and a
free-standing tree
Docking zone
:
Location (1) directly next to the house
A
No-go area
:
Installation around the free-standing tree,
based on a linking section installed at right
angles to the edge.
Pond
:
Clearance from the perimeter wire (2) to
the pond
B
:
100 cm
Wire clearances
:
Clearance to obstacles that can be
travelled on such as patios and paths:
0 cm
Clearance to high obstacles:
27 cm
Clearance around the tree:
37 cm
Clearance to the pond:
100 cm
Confined area
:
Installation of a corridor (3) (
Wire clearance:
80 cm
Guide loops
:
Installation of two guide loops (4).
Minimum distance from the corridor
entrance:
2 m
Note the minimum clearance to corners.
(
Programming
:
Define the total size of the mowing area,
program two starting points (5) (close to
the docking station and in the contorted
corner near the pond) – starting frequency
2 of 10 operations in each case (
Particularities
:
Unmown areas, e.g. B around the pond
must be mown manually on a regular basis
or cut using a suitable lawn trimmer.