Calling up code 1
Note
&
On weather-compensated control
units, codes are displayed as plain
text.
&
Codes that are irrelevant due to the
system equipment level or the set-
ting of other codes will not be dis-
played.
&
Heating systems with one heating
circuit without mixer and one heat-
ing circuit with mixer:
Initially, the possible coding
addresses "A0" to "d4" for the heat-
ing circuit without mixer A1 are
scanned; then the coding addresses
for the heating circuit with mixer M2
are scanned.
Press the following keys:
1.
K
+
L
simultaneously for
approx. 2 s.
2.
a
/
b
for the required coding
address; the address
flashes.
3.
d
to confirm.
4.
a
/
b
for the selected value.
5.
d
to confirm; the display
briefly shows "
accepted
"
(weather-compensated
control unit); the address
flashes again.
6.
a
/
b
for the selection of further
addresses.
7.
K
+
L
press simultaneously for
approx. 1 s; code 1 is ter-
minated.
Overview
Coding
Coding in the delivered condition
Possible change
System design
00:2
System version 1:
1 heating circuit without
mixer A1, with DHW
heating
00:4
System version 2, 5:
1 heating circuit with
mixer M2, with DHW
heating
00:6
System version 3, 4:
1 heating circuit without
mixer A1 and 1 heating
circuit with mixer M2, with
DHW heating
Code 1
41
Coding
5692
731
GB
Summary of Contents for VITODENS 333-F WS3A
Page 113: ...Parts lists cont 113 Parts lists 5692 731 GB ...
Page 114: ...Parts lists cont 114 Parts lists 5692 731 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 731 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 731 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 731 GB ...