Coding in the delivered condition
Possible change
91:0
No external heating pro-
gram changeover via
external extension (only
for weather-compen-
sated control units)
91:1
The external heating pro-
gram changeover affects
the heating circuit without
mixer
91:2
The external heating pro-
gram changeover affects
the heating circuit with
mixer
91:3
The external heating pro-
gram changeover affects
the heating circuit without
mixer and the heating cir-
cuit with mixer
95:0
Without Vitocom 100
communication inter-
face
95:1
With Vitocom 100 com-
munication interface
(automatic recognition)
97:0
The outside tempera-
ture of the sensor con-
nected to the control
unit is utilised internally
(only for weather-com-
pensated control units)
97:1
The outside temperature
is accepted by the LON
BUS
97:2
The outside temperature
of the sensor connected
to the control unit will be
utilised internally and is
transmitted via the LON
BUS to any connected
Vitotronic 200-H
98:1
Viessmann system
number (in conjunction
with monitoring several
systems via
Vitocom 300)
98:1
to
98:5
System number adjusta-
ble from 1 to 5
9b:0
Minimum set boiler
water temperature for
external demand
9b:1
to
9b:127
Minimum set boiler water
temperature adjustable
from 1 to 127 °C
Code 2
(cont.)
51
Coding
5692
731
GB
Summary of Contents for VITODENS 333-F WS3A
Page 113: ...Parts lists cont 113 Parts lists 5692 731 GB ...
Page 114: ...Parts lists cont 114 Parts lists 5692 731 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 731 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 731 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 731 GB ...