Fault
code
on the
display
Const.
Weath.-
comp.
System char-
acteristics
Cause
Measures
59
X
X
No DHW heat-
ing
Outlet tem-
perature
sensor lead
broken
Check sensors
(see page 83)
92
X
X
Control mode
Collector
temperature
sensor short
circuit; con-
nects to the
Vitosolic at
S1
Check the sensor
at the Vitosolic.
93
X
X
Control mode
Cylinder
temperature
sensor
shorted out;
connects to
the Vitosolic
at S3
Check the sensor
at the Vitosolic.
94
X
X
Control mode
Temperature
sensor
shorted out;
connects to
the Vitosolic
at S2
Check the sensor
at the Vitosolic.
9A
X
X
Control mode
Collector
temperature
sensor lead
broken; con-
nects to the
Vitosolic at
S1
Check the sensor
at the Vitosolic.
9b
X
X
Control mode
Cylinder
temperature
sensor lead
broken; con-
nects to the
Vitosolic at
S3
Check the sensor
at the Vitosolic.
Fault codes
(cont.)
75
Troubleshooting
5692
731
GB
Summary of Contents for VITODENS 333-F WS3A
Page 113: ...Parts lists cont 113 Parts lists 5692 731 GB ...
Page 114: ...Parts lists cont 114 Parts lists 5692 731 GB ...
Page 115: ...Parts lists cont 115 Parts lists 5692 731 GB ...
Page 116: ...Parts lists cont 116 Parts lists 5692 731 GB ...
Page 117: ...Parts lists cont 117 Parts lists 5692 731 GB ...