1.
Remove the screw at the top of the
boiler.
2.
Press down the springs on the
underside of the boiler and remove
the front panel.
3.
Lift the front panel from the wall
mounting frame.
Burner removal
1.
Switch OFF the mains power.
2.
Close the gas shut-off valve and
safeguard against reopening.
3.
Pull electrical cables from fan
motor
A
, gas train
B
, and ignition
unit
E
.
4.
Remove connection hose from air
pressure switch
D
.