53
7.
!
Please note
Ensure the specified mini-
mum lengths above the roof
are observed.
Never trim roof outlets
above the roof.
Roof outlet
■ Use universal tiles or air vent tiles
with pipe outlets.
■ Position balanced flue slide cou-
pling
3
underneath the roof out-
let.
■ Install pipe outlets for Klöber or
universal roof tiles in accordance
with manufacturer's instructions.
■ Position the roof outlet onto the
roof tiles from above.
■ Connect the external wall pipe
from below.
Elbow in the external routing for
a short roof overhang
■ Elbow with 45° bend
qR
: Fit bal-
anced flue inspection piece
7
.
■ Elbow with 30° bend
qR
: Bal-
anced flue inspection piece
7
not required.
■ Fit external wall terminal
qE
Routing over an external wall
(cont.)
5780 223 GB