17
Vitodens 100-W, type B1HA and B1KA, Vitodens 111-W
Rated heating output
kW
26.0
26.0
30.0
35.0
System size 60/100
m
15
15
15
15
System size 80/125
m
25
20
20
20
Vitodens 200-W, 222-F and 242-F
Rated heating
output
kW
13
19
26
35
45
60
80
100
System size
60/100
m
20
20
20
15
—
—
—
—
System size
80/125
m
25
25
25
25
20
15
—
—
System size
100/150
m
—
—
—
—
25
20
20
20
Note
For alternative system sizes, a bal-
anced flue adaptor is required.
The following components are taken
into consideration for the maximum flue
lengths:
■ Balanced flue connection pipe 0.5 m
long
■ 1 balanced flue bend 87° and 1 sup-
port bend 87°
or
■ 2 balanced flue bends 45° and 1 sup-
port bend 87°
Subtract other bends, tees and straight
lengths from the maximum length using
the following values:
■ Balanced flue connection pipe 0.5 m
long: 1 m
■ Balanced flue connection pipe 1 m
long: 2 m
■ Balanced flue bends 45°: 0.5 m
■ Balanced flue bends 87°: 1 m
■ Balanced flue inspection tee: 1.5 m
Routing through a shaft
(cont.)