Supply air
B
Flue gas
Rated heating out-
put
kW
≤50 ≥50
a (min.)
mm
400 1000
1
Boiler flue connection
2
Balanced flue roof outlet
3
Pipe outlets for Klöber roof
tiles
Provide a suitable Klöber roof tile
on site.
or
Universal roof tile
or
Flat roof collar
4
Balanced flue inspection piece
,
straight
5
Balanced flue slide coupling
6
Balanced flue bend
87° or 2 x 45°
Balanced flue pipe
1 m long
0.5 m long
7
Fixing clamp
Balanced flue adaptor
7
60/100 mm to
7
80/125 mm
Maximum flue length
Vitodens 100-W, type WB1B:
10 m
Vitodens 100-W, type B1HA and B1KA, Vitodens 111-W
Rated heating output
kW
19
26.0
30.0
35.0
System size 60/100
m
10
10
8
8
System size 80/125
m
13
13
11
11
Vertical outlet for pitched or flat roofs
(cont.)
5780 223 GB