77
Electric booster heater
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
Service
"Enable instantaneous heating water
heater"
7900
0
"Enable electric heaters for DHW heat-
ing"
7901
0
"Enable instant. heating water heater for
central heating"
7902
1
Start delay instantaneous heating water
heater
7905
30 min
"Max. output instantaneous heating wa-
ter heater"
7907
3
"Output for instant. heating water heater
at power-OFF"
790 A
0
"Dual mode temp instant. heating water
heater"
790 B
500 (
≙
50 °C)
Internal hydraulics
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
Heat pump for drying a building
7300
0
Time program for screed drying
7303
0
Set flow temperature for external demand
730C
500 (
≙
50 °C)
Enable 3-way diverter valve, heating/DHW
730D
0
Start threshold
730E
300 K
·
min
Cycle rate heating circuit pumps
7319
0
Operating mode, secondary pump
7340
0
Secondary circuit pump type
735A
0
Starting time, high efficiency circulation
pump
7365
5
Operating mode, secondary pump 2
73C0
0
Primary source
Parameter
Code
Delivered condition Commission-
ing
Maintenance/
service
Primary source mode
7400
0
Primary source ctrl strategy
7401
0
Primary source start performance
7414
100 %
Primary circuit pump type
745A
Do not adjust.
Min. primary circuit inlet temperature in op-
eration
7470
Do not adjust.
Response delay, probe protection
7471
Do not adjust.
Commissioning/service reports
Control parameter report
(cont.)
5855006
Appendix