59
Parameters for swimming pool water heating
Parameter
Setting
"System definition"
Ó
"External extension 7010"
"1"
or
"3"
"Swimming pool 7008"
"1"
Parameters for ice store system
Parameter
Setting
"System definition"
Ó
"Select primary source 7030"
"1"
"External extension 7010"
"2"
Parameter
Setting
"Solar"
Ó
"Type solar control unit 7A00"
"2"
Possibly set additional parameters.
Parameter
Setting
"System definition"
Ó
"Start hysteresis solar air absorber 7031"
"0"
to
"500"
(
≙
0 to 50 K)
"Min. runtime to suppress summer mode 7035"
"0"
to
"1440"
min
"Last calendar week for summer mode 7036"
Calendar week
"1"
to
"53"
Parameters for ventilation with Vitovent 200-C
Parameter
Setting
"Ventilation"
Ó
"Vitovent enable 7D00"
"2"
Vitovent 200-C
Further enabling for Vitovent 200-C if necessary
Parameter
Setting
"Ventilation"
Ó
"Enable preheater bank electric 7D01"
"0"
Defrosting without preheating coil
(
"Strategy, passive frost pro-
tection 7D2C"
)
"1"
Frost protection with preheating
coil; defrosting via bypass
"2"
Frost protection with preheating
coil; comfort function
"Strategy, passive frost protection 7D2C"
"0"
Fans OFF
"1"
Defrosting via bypass
"2"
Supply air fan OFF
"Type of heat exchanger 7D2E"
"0"
Countercurrent heat exchanger
"1"
Enthalpy heat exchanger
"Installation position 7D2F"
"0"
Ceiling mounting
"1"
Wall mounting
"Function, external 230 V input, ventilation 7D3A"
"1"
External switch (bathroom switch)
enabled
Commissioning, inspection, maintenance
Commissioning the system
(cont.)
5855006