Compressor
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Enable compressor"
5000
1
"Evaporator temperature for
defrost end"
5010
250 (
≙
25 °C)
"Enable use of compressor
stage"
5012
15
"Output compressor stage"
5030
Rated heating
output accord-
ing to type
plate
"Primary source output"
5043
0
External heat generator
Parameter
Code
Delivered
condition
Commis-
sioning
Mainte-
nance/
Service
"Enable external heat source"
7B00
0
"Priority ext. heat source/in-
stant. heating water heater"
7B01
1
"Dual mode temperature ex-
ternal heat source"
7B02
100 (
≙
10 °C)
"Enable external heat source
for DHW heating"
7B0D
0
"Shutdown limit, heat pump
dual mode"
7B0F
–500
(
≙
–50 °C)
"Enable boiler water tempera-
ture sensor"
7B11
1