8
Assembly
5777744-03 GB Subject to technical changes!
Â
In the case of floor elements (
2
) with 1 and 2-side
connection, fill the connection point (
3
) with the
enclosed sealant during assembly.
Â
Do not put any load on the floor elements to be as
-
sembled during tensioning.
Â
Make sure that the floor elements to be assembled
can move freely.
Â
Push floor elements (
4
) together.
Â
Tighten eccentric cam lock (
5
) on the exterior.
Â
If necessary, push the opposing side of the floor ele
-
ment with a pry bar.
Â
Make sure that the floor elements are not damaged.
Â
Tighten the eccentric cam lock on the opposing
exterior side.
Â
Tighten interior eccentric cam locks.
4.5 Assembling room elements
Connect room elements as follows:
Â
Activate eccentric cam locks from inside of room.
First, only operate the centre locks to enable the
alignment of the walls.
Â
Check whether the room elements’ eccentric cam
locks can be opened by turning left with Allen key.
Â
Make sure that the room elements are not more
than 12 mm apart from one another.
Â
Push room elements together and close eccentric
cam locks by turning right.
4.6
Assembling floor elements
L
Floor elements with stainless steel top plate are fit with
joint tape on the overlapping on the spring side.
Â
Make sure that there is no protective film on the joint
tape.
Â
Make sure that the joint tape (
1
) are not damaged
during assembly.