Assembly
5777744-03 GB Subject to technical changes!
Â
Adhere enclosed sealant (
1
) to cleaned edge of the
inner floor panel.
Â
Remove protective film from joint tape.
Â
Begin wall assembly with corner element.
Â
Push elements together and tighten eccentric cam
locks. First, only operate the centre locks to enable
the alignment of the walls.
Â
Align wall element horizontally and vertically.
Â
In the case of longer room elements, there may be
protrusions at the corners caused by natural toler-
ance. We recommend starting with the assembly of
the room at the corner areas. Connect the elements
with the floor and the ceiling according to the order
defined in the drawing. Install the final walls from
inside to outside with the aid of vacuum suction
devices. Make sure that the last wall set is flush with
the other room walls at the upper edge.
4.9 Assembling partition wall of combination
rooms without tongue and groove system
Â
B
A
Place partition wall at intended location.
Â
Fasten partition wall to the wall, ceiling and floor ele
-
ments with the enclosed fastening profiles (
2
).
Â
Make sure that the cover plate (
1
) is interrupted
between the elements to prevent condensation from
forming.
4.10 Mounting the door
L
The single-leaf door is delivered pre-mounted in the
door frame.
Â
Align door frame horizontally and vertically.
4.11 Mounting ceiling elements
Â
Place ceiling element (
1
) onto wall elements (
2
) and
tighten eccentric cam locks (
3
).
If any of the elements become displaced:
Â
Open the eccentric cam locks and align the ele-
ments.
Â
Retighten the eccentric cam locks in the following
order: wall/wall, wall/ceiling and wall/floor.
1
1
2
2
2
2
3