13
Electrical connections
5777744-03 GB Subject to technical changes!
4.19 Mechanical work on the door or porthole
DANGER!
Risk of death due to electric
shock from damaged wires!
f
Do not conduct any mechanical
work
(such as drilling or sawing) on the
inside or outside of the door or port-
hole in the safety zone (
1
).
L
100 mm
100 mm
Electrical components are foamed in place in the
grey-marked safety zone
1
. Damage to the electrical
components or wires poses the risk of electric shock.
Â
Observe safety zone (
1
) before commencing me
-
chanical work on the door or porthole.
Â
Makes sure that mechanical work will only be con-
ducted outside of the safety zone.
4.20 Rearranging the luminaries
L
1
2
Moisture-proof luminaries and junction box are mount-
ed at the factory on the inside of the door frame.
L
The junction box with luminaries can be displaced by
90°.
Â
Pull the luminary (
1
) from the mounting plate (
2
).
Â
Remove the plug from the pre-punched fixing holes.
Â
Fasten mounting plate in its new position.
Â
Clip luminary to mounting plate.
5 Electrical connections
DANGER!
Risk of death due to electric
shock!
f
Only have work for the mains
connection and installation of protec-
tive measures (GFCI circuit breaker)
conducted by a specialised electrical
contractor.
f
Observe the applicable regula-
tions (EN, ISO, VDE, etc.) and con
-
nection conditions from the relevant
energy supply company.
DANGER!
Risk of death due to electric
shock!
f
Before establishing the mains
connection, shut off the mains power
and secure it to prevent it from being
turned back on.