Assembly
5777744-03 GB Subject to technical changes!
4.12 Seal operating apertures in the cam locks in
the wall and ceiling elements
Â
Fill operating apertures 3 with the supplied heat
insulation foam fillers (
2
).
Â
Seal operating apertures with plastic plugs (
1
).
4.13
Mount doorsill (for rooms with floor ele
-
ments)
DANGER!
Risk of death due to electric
shock!
f
Only drill out the intended holes in
the stainless steel doorsill.
f
Do not drill any additional holes.
Â
Place the stainless steel doorsill (
1
) in the middle
between the door soffit on the floor element and
align.
Â
Use the stainless steel doorsill as a template for fix
-
ing holes (Ø 3.3 mm) and drill out.
Â
Remove drilling chips.
Â
In order to prevent moisture from getting in, apply
sealing strip with the enclosed sealant (
2
) on the
entire surface of the bottom of the doorsill.
Â
Distribute sealing strip.
Â
Lay stainless steel doorsill onto floor element and
align it.
Â
Fasten stainless steel doorsill with enclosed rivets.
Â
Seal stainless steel doorsill with enclosed sealant:
between door soffit and doorsill
between floor and doorsill
Â
Remove any sealant that escapes.
4.14 Remove transport securing plates
L
The magnetic sealing frames on the doors are pro-
tected from mechanical damage by securing plates.
Before initial operation or door adjustment:
Â
Remove transport securing plates (
1
).