12
Assembly
5777744-03 GB Subject to technical changes!
4.15 Adjusting the door
1
2
3
1
Adjust hinges when the door is closed in order to com-
pensate for deviations if:
the magnet sealing profile is not placed evenly all
the way around
the sealing lip of the floor seal is not lying on the
sill or on-site floor.
Adjust hinges as follows:
Â
Remove cover caps (
1
) from door hinges.
Â
Open door.
Â
Insert thin pin, small Allen key or similar into open-
ing (
3
) in the cap in order to loosen the cap seal.
Â
Loosen the screws (
2
).
Adjust the door leaf in depth and horizontal posi-
tion using the screws (
2
).
Adjust the door leaf vertically with the hinge pin.
Adjust door vertically:
Â
Turn hinge pin with Allen key (8 mm) until the door
has the desired height.
Â
Make sure that the hinge can move easily in all
adjustment areas.
Â
Adjust all of the door’s hinges.
L
Maximum adjustment range: +/- 3 mm.
4.16 Light test
Â
Conduct a light test to check whether light gets into
the dark room through an open seal point.
4.17 Attaching the cover caps
Â
Place the cover caps onto the hinge so they are
centred.
Â
Fit the narrow side of the cover caps in the recess in
the hinge housing into slide blocks.
Â
Lock the mounting lugs into place by pushing up or
down on the cover caps.
4.18 Fastening the striker
L
The striker of the rotary lever lock is adjusted at the
factory.
Â
After assembly or door adjustment, check whether
lug of the rotary lever lock clicks into place behind
the striker (
2
).
If necessary, readjust the striker as follows:
Â
loosen the striker screws (
3
).
Â
If necessary, place a spacer (
1
) between the door
frame and striker.
Â
Fix the striker into the slots with screws (
3
) and
tighten the screws.
Â
Check whether the door is tight.
Â
Pre-drill fastening for round holes (Ø 3.7 mm).
Â
Additionally fix the striker into the slots with the
enclosed screws (
4
).