5
Transport
5777744-03 GB Subject to technical changes!
3 Transport
Â
Only carry room elements from the bottom to pre-
vent panels from separating.
3.1 Delivery
Delivery condition:
Delivery in individual packaging units
Individual elements must be marked with stickers
or numbers.
The door panel (single-leaf) is pre-mounted in
the door frame.
The following are built into the door frame:
Control panel
Moisture-proof luminaries
Junction box
Mounting accessories are packaged separately.
The control panel contains:
Light switch
Thermometer
Pressure equalisation valve
Door frame heating and pressure compensation
valve (optional for wall thickness 80)
3.1.1 Unpacking
Before and during the unpacking:
Â
comply with the safety and environmental regula-
tions at the installation site.
Â
Check TectoCell cold rooms and deep-freezing
rooms for transport damages with a visual inspec-
tion.
Â
In order to process warranty claims, report faults
(with photos, for instance) to the manufacturer and
indicate the manufacturer number and type designa-
tion.
Â
"Provisions in the event of damage" must be ob-
served!
Â
Observe the "General conditions for transport dam-
age and hidden transport damage".
Â
Check packaging material for loose parts after
unpacking.
Â
Dispose of packaging material in an environmentally
compatible way according to local regulations.
NOTE
Damage to the door!
f
If no door stop has been installed,
please make sure to carefully open
the door in order to prevent dam-
ages to the door or the wall.
NOTE
Damage from defective cold
rooms and deep-freezing rooms!
f
Ensure that only trained
qualified personnel operate the
Tecto cold rooms and deep-freezing rooms.
f
Use TectoCell cold rooms and
deep-freezing rooms exclusively in
original condition without unauthor-
ized modifications and in technically
perfect condition.
Â
Follow Installation and Operating Instructions.
Â
Have mounting, maintenance, cleaning, and repair
work performed exclusively by trained specialists.
2.1 Intended use
Use the TectoCell cold rooms and deep-freezing rooms
exclusively for cooling suitable refrigerated products.
Use TectoCell cold rooms and deep-freezing rooms
exclusively for:
commercial purposes
for the specified temperature range
for stationary use
2.2 Foreseeable Misuse
Do not use TectoCell cold rooms and deep-freezing
rooms for mobile uses.Do not install
TectoCell cold rooms and deep-freezing rooms in
areas exposed to the effects of weathering.
Any use which does not comply with the conditions of
use discussed during the sales process is deemed to