51
Matching the control unit to the heating system
The control unit must be matched to the
equipment level of the system. Various
system components are recognised
automatically by the control unit and the
relevant codes are adjusted automati-
cally.
■ For the selection of an appropriate
scheme, see the following diagrams.
■ For coding steps, see page 66.
System version 1
One heating circuit without mixer A1, with/without DHW heating, with low loss
header
1
2
3
4
6
5
9
qP
8
7
ID: 4605139_1103_02
1
Vitodens 200-W
2
Outside temperature sensor (only
for weather-compensated control
units)
or
Vitotrol 100 (only for constant tem-
perature control units)
3
Boiler circuit pump
4
Circulation pump for cylinder heat-
ing
5
DHW cylinder
6
Cylinder temperature sensor
7
Heating circuit without mixer A1
(heating circuit 1)
8
Heating circuit pump A1
9
Low loss header
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5623 520 GB
Service