112
Checking the fuse
A
F1
Fig. 57
1.
Turn off the ON/OFF switch.
2.
Depending on the configuration: Move program-
ming unit together with bracket to service position.
3.
Pivot the HMU heat management unit down.
4.
Remove cover
A
.
5.
Check fuse F1 (see connection and wiring dia-
gram).
Danger
Incorrect or improperly fitted fuses can lead
to an increased risk of fire.
■
Insert fuses without using any force. Posi-
tion fuses correctly.
■
Only use structurally identical types with
the specified response characteristics.
Troubleshooting
Repairs
(cont.)
5593201
Diagnosis