13
6167 818 - 10
Vitodens 100-W, B1HE/B1KE Combi Installation/Service
Installation
Mounting the Boiler and Making Connections
Removing the front panel
1. Unlock the front panel on the underside (push in),
using a screwdriver or similar tool.
2. Swivel the front panel forwards slightly and lift
away
upwards.
Note:
Do not remove protective caps from
connections on the heating water side and from the
gas connection until you are about to commence
installation.
Start-up and Maintenance
Installing the wall mounting bracket
The Vitodens 100-W can be wall-mounted on a concrete
wall.
Note:
The enclosed screws and rawl plugs are only
suitable for concrete. For other construction
materials, use bolts and anchors that are suitable
for 196 lb. (86 kg) loads.
Installation of mounting bracket on brick/concrete wall
1. Mark out the rawl plug holes.
2. Drill holes
7
e
in. (
7
10 mm) and insert the rawl plugs
supplied.
3. Fit the wall mounting bracket with the screws supplied.
CAUTION
Whichever mounting method is used, ensure that the
bracket is tightly and securely fastened to wall. Failure
to secure boiler properly could cause boiler to loosen,
posing a severe safety hazard.
Fitting the wall mounting bracket
Following are the installation instructions for the mounting
bracket on each material. See the instructions applicable
to your installation requirements.
Note:
Check the condition of the wall where the boiler is
to be installed. For the suitability of the supplied
rawl plugs for various building materials, see the
manufacturer’s
instructions.
For other construction materials, use fixing
materials with sufficient load bearing capacity.