4
6167 818 - 10
Vitodens 100-W, B1HE/B1KE Combi Installation/Service
Table of Contents
Removing the Burner
................................................50
Checking the Burner Gasket and Flame Body Assembly
..51
Checking and Adjusting the Ignition and
Ionization Electrodes
.................................................53
Checking the Flue Gas Flapper
...................................53
Cleaning the Heating Surfaces
..................................54
Check Condensate Drain / Cleaning the Siphon Trays
....55
Installing the Burner
................................................56
Checking the Neutralization System
(if Installed) ..........57
Check the Flow Limiter
(only for gas condensing
combi boiler) ............................................................57
Checking the Expansion Tank
(on site)
and System
Pressure
..................................................................58
Checking the Safety Valve Function
...........................58
Checking All Gas Equipment for Leaks at
System Presure
.......................................................58
Fitting the Front Panel
...............................................58
Checking the Combustion Quality
.............................59
Checking the CO
2
Content / Relay Tests
.....................60
Clock Natural Gas Meter
...........................................60
Calling Up and Resetting the Maintenance Display
........60
Instructing the System User
.......................................61
Calling Up Parameters
...............................................61
General
...................................................................62
Boiler
......................................................................63
DHW
......................................................................65
Service Menu
...........................................................67
Checking Outputs (actuator test)
................................67
Fault Display on the Programming Unit
........................69
Overview of Electronic Modules
..................................71
Fault Messages
........................................................72
Repairs
....................................................................82
Opening the Junction Box
.........................................89
Boiler Functions
.......................................................91
DHW Heating
...........................................................92
Increased DHW Hygiene
..........................................92
Call for Heat
........................................................ 92
Overview of the Modules
..................................... 93
HMU Heat Management Unit
.................................... 94
BCU Burner Control Unit
........................................... 95
Wiring Panel
............................................................96
B1HE Models 85 / 120 / 150 / 199
............................97
B1KE Models 120 / 199
............................................98
Service Reports ........................................................
99
Technical Data .......................................................
100
Parts List
..............................................................103
Lighting and Operating Instructions ...........................
125
Service
System Configuration (parameters)
Diagnostics and Service Checks
Troubleshooting
Function Descriptions
Wiring Diagrams
Maintenance Record
Specification
Parts
Additional Information
Page