32
B
Gravel bed as condensate soak-
away
C
Concrete foundations (see technical
guide)
D
Drainage pipe DN 100 (only with
entry points below ground level)
D
Rubber mounts (supplied)
Note
We recommend letting condensate drain
away freely (without condensate drain
pipe).
Wall mounting
Installation must
only
be performed with
the bracket set suitable for wall mounting
(accessory).
Separate installation instructions
Installing the internal unit
!
Please note
Avoid damaging the appliance
during transportation.
Never
put weight on top of the
appliance.
Installation room requirements
!
Please note
The installation room must be dry
and free from the risk of frost.
Ensure ambient temperatures 0
to 35 ºC.
!
Please note
Avoid risk of explosion due to
dust, gases and vapours
in the installation room.
Minimum room volume (to
DIN EN 378):
Type AWB/AWB-
AC
Minimum room
volume in m
3
201.B04
2.7
201.B07
4.8
201.B10
6.7
201.B13
6.7
Installation sequence
Installing the external unit
(cont.)
5604 692 GB