127
Type AWB/AWB-AC
201.B04
201.B07
201.B10
201.B13
Electrical values
Internal unit
Heat pump control
unit/PCB
■ Rated voltage, con-
trol unit/PCB
1/N/PE 230 V/50 Hz
■ Fuse protection,
power supply
1xB16A
■ Fuse, internal
6.3A (slow)/250 V
Instantaneous heat-
ing water heater
Only for type AWB-AC
■ Rated voltage
1/N/PE 230 V/50 Hz
3/N/PE 400 V/50 Hz
■ Heating output
kW
8.8
8.8
8.8
8.8
■ Fuse protection,
power supply
3xB16A
3xB16A
3xB16A
3xB16A
Electrical power con-
sumption
■ Fan (max.)
W
65
70
130
130
■ External unit (max.)
W
3.0
3.6
5.8
5.8
■ Secondary pump at
stage 3/2/1
W
132/92/62
132/92/62
132/92/62
132/92/62
■ Control unit/PCB,
external unit (max.)
W
150
150
150
150
■ Control unit/PCB,
internal unit (max.)
W
5
5
5
5
■ Max. output, control
unit/PCB
W
1000
1000
1000
1000
Specification
Specification
(cont.)
5604 692 GB
Service