67009600-EN - Edition 2015 - Rev. 1.0
8
VX2300 Digital System - “2 Wire” Audio/Video Door Entry System
VX2300 Digital System - Installation handbook
SIGNALS ON SYSTEM CONNECTION TERMINALS
1
Common terminal for addresses 1..8 (switch 6 = OFF)
or 65..72 (switch 6 = ON)
E
Addresses 5,13,21,29,37,45,53, 61 (switch 6 = OFF)
Addresses 69,77,85,93,101,109,117, 125 (switch 6 = ON)
2
Common terminal for addresses 9..16 (switch 6 = OFF)
or 73..80 (switch 6 = ON)
F
Addresses 6,14,22,30,38,46,54, 62 (switch 6 = OFF)
Addresses 70,78,86,94,102,110,118, 126 (switch 6 = ON)
3
Common terminal for addresses 17..24 (switch 6 = OFF)
or 81..88 (switch 6 = ON)
G
Addresses 7,15,23,31,39,47,55, 63 (switch 6 = OFF)
Addresses 71,79,87,95,103,111,119, 127 (switch 6 = ON)
4
Common terminal for addresses 25..32 (switch 6 = OFF)
or 89..96 (switch 6 = ON)
H
Addresses 8,16,24,32,40,48,56, 64 (switch 6 = OFF)
Addresses 72,80,88,96,104,112,120, 128 (switch 6 = ON)
5
Common terminal for addresses 33..40 (switch 6 = OFF)
or 97..104 (switch 6 = ON)
BUS
BUS Connection terminals
6
Common terminal for addresses 41..48 (switch 6 = OFF)
or 105..112 (switch 6 = ON)
BUS
7
Common terminal for addresses 49..56 (switch 6 = OFF)
or 113..120 (switch 6 = ON)
PTE
Active low input push to exit signal
8
Common terminal for addresses 57..64 (switch 6 = OFF)
or 121..128 (switch 6 = ON)
GND
Ground
A
Addresses 1,9,17,25,33,41,49, 57 (switch 6 = OFF)
C
Door open relay common contact
Max 12-24
Vac/dc 3A
Addresses 65,73,81,89,97,105,113, 121 (switch 6 = ON)
B
Addresses 2,10,18,26,34,42,50, 58 (switch 6 = OFF)
NC
Door open relay normally closed contact
Addresses 66,74,82,90,98,106,114, 122 (switch 6 = ON)
C
Addresses 3,11,19,27,35,43,51, 59 (switch 6 = OFF)
NO
Door open relay normally open contact
Addresses 67,75,83,91,99,107,115, 123 (switch 6 = ON)
D
Addresses 4,12,20,28,36,44,52, 60 (switch 6 = OFF)
VAUX
35Vdc power supply input (if used, the module is
powered locally and not from the BUS)
Addresses 68,76,84,92,100,108,116, 124 (switch 6 = ON)
BUTTON MATRIX
The button, when pressed, will generate a call to a specific address according to the terminals to which the button is connected: i.e.
a button connected between terminals “2” and “B”, when pressed will generate a call to the address 10 if the dip-switch 6= OFF or a
call to the address 74 if the switch 6=ON.
SW6
OFF
1
2
3
4
5
6
7
8
A
1
9
17
25
33
41
49
57
B
2
10
18
26
34
42
50
58
C
3
11
19
27
35
43
51
59
D
4
12
20
28
36
44
52
60
E
5
13
21
29
37
45
53
61
F
6
14
22
30
38
46
54
62
G
7
15
23
31
39
47
55
63
H
8
16
24
32
40
48
56
64
SW6
ON
1
2
3
4
5
6
7
8
A
65
73
81
89
97
105
113
121
B
66
74
82
90
98
106
114
122
C
67
75
83
91
99
107
115
123
D
68
76
84
92
100
108
116
124
E
69
77
85
93
101
109
117
125
F
70
78
86
94
102
110
118
126
G
71
79
87
95
103
111
119
127
H
72
80
88
96
104
112
120
128
Art. 4303N
Speaker unit module with built-in functional to digital interface