67009600-EN - Edition 2015 - Rev. 1.0
67
VX2300 Digital System - “2 Wire” Audio/Video Door Entry System
VX2300 Digital System - Installation handbook
PROGRAMMING
The 8 way dip-switch enables the setting of the device address and the main door panel type selection.
DIP-SW
Switch status
Block
Address
With Sw8 = ON
1
2
3
4
Address
ON
OFF OFF OFF
1
1..10
OFF
ON
OFF OFF
2
11..20
ON
ON
OFF OFF
3
21..30
OFF OFF
ON
OFF
4
31..40
ON
OFF
ON
OFF
5
41..50
OFF
ON
ON
OFF
6
51..60
ON
ON
ON
OFF
7
61..70
OFF OFF OFF
ON
8
71..80
When the block is set to work with a main door panel of tradi-
tional type (Art. 4303N), switch 8 on the Art. 4303N must be set to
ON (Main entrances only). Each block can have a maximum of 10
apartments and the range of the addresses for each block is limit-
ed depending on the Art. 2306N address (i.e. the intercoms/vide-
ophones/relay connected to the block with Art. 2306N address 1
have apartment addresses between 1 & 10, block with Art. 2306N
address 3 must have apartment addresses between 21 and 30 etc).
DIP-SW
Switch status Main door panel type
OFF*
Digital main door panel (Art. 4302,
Art. 4302V, Art. 4302R, Art. 4302RV)
ON
Traditional main door panel (Art. 4303)
* On the digital panels connected to the main bus (BUS-M) enable
the “main” mode in the programming menu. When “main” mode is
enabled the user programming requests to enter the block address
in addition to the device (intercom/videophone/relay) address.
CONTROLS
Jumpers J4 and J2 are used to adjust the signal amplification
and the termination of the main BUS (BUS-M).
SPECIFICATION
Housing/Mounting:
9 Module A Type DIN box / DIN Bar or
directly to the wall
Push Buttons:
N/A
Programming:
By 8 way dip-switch
Controls:
Amplification (J4) and termination
(J2) main bus line
BUS-M
Power Supply:
From specific power supply
Working Temperature:
-10 +50°C
J4 BUS-M AMPLIFICATION
Position
Amplification
level
Low
Medium
High
J2 BUS-M TERMINATION
Position
Termination
Disabled
Enabled
Art. 2306N
Block exchanger