67009600-EN - Edition 2015 - Rev. 1.0
4
VX2300 Digital System - “2 Wire” Audio/Video Door Entry System
VX2300 Digital System - Installation handbook
Art. 4302N
Digital call panel
PROGRAMMING
The programming of the unit can be carried out from the panel keypad or a PC via RS-232 serial connection and the PC programming
software. The programming step 6.3 is only available if the panel is programmed as “MAIN” (main door panel in a system with main en-
trance and secondary entrances using Art. 2306 exchangers). On systems with main and secondary entrances, panels at the main entranc-
es must be set as “MAIN” while panels at the block entrances must be set as “STAND.” (standard). The main door panels call all the apart-
ments on the system so for each apartment the block address (Art. 2306 address) must be programmed in addition to the device address.
PROGRAMMING VIA PANEL KEYPAD
Prg.
step
Display
Operation
1
Enter flat nr.
<- or search ->
The panel is in stand-by.
Press “0” button.
2
code:******
Type the ENGINEER’s code (factory default six times “1”) to access to the programming menù
(the display will show a star for each digit typed).
Press “ENTER” button.
3
code:******
new:
If required type a new ENGINEER’s code (up to 6 digits).
Press “ENTER” button.
4
trade c.:xxxx
new:
Type the new TRADE CODE (up to 6 digits)
1
or leave unchanged (if existing).
Press “ENTER” button.
5
0=stand. 1=main
0=new
Type 0 if the panel is used on system with 1 or more entrances on the same level or on
secondary entrances on systems with main and secondary entrances. Type 1 if the panel is
used as main entrance on a system with main entrances and secondary entrances.
Press “ENTER” button.
6
mem.location:
Type a memory location to program (1..998)
2
or nothing to jump to programming step 6.
Press “ENTER” button.
6.1
flat:ffffff
new:
Type the new “FLAT CODE” (up to 6 digits) or leave unchanged (if existing). The “FLAT CODE” is the number
used by the visitor to call the flat by typing the number into the door panel keypad and pressing enter.
Press “ENTER” button.
6.2
id phone:iii
new:
Type the new “ID PHONE” (up to 3 digits)
3
or leave unchanged (if existing). The “ID PHONE” is
the ID of the unit (intercom or videophone) located inside the flat.
Press “ENTER” button.
6.3
id block:bb
new:
Type the new “ID BLOCK” (2 digit) or leave unchanged (if existing). The “ID BLOCK” is the ID of
the block (set on the Art. 2306 relative to the block) to which the unit (intercom, videophone
or relay) is connected. This setting is available only when main mode is set.
Press “ENTER” button.
6.4
door code:dddddd
new:
Type the new “DOOR CODE” (up to 6 digits) or leave unchanged (if existing). The “DOOR CODE”
is the code that allows the user to open the door from the outside by typing it in at the door
panel keypad. (Pressing CODE followed by the code and then enter).
Press “ENTER” button.
6.5
user name:
uuuuuuuuuuuuuuuu
Type the new “USER NAME” (up to 16 characters) or leave unchanged (if existing). The “USER
NAME” is the name shown when the visitor use the repertory name facility (only on Art. 4302R).
Press “ENTER”, the programming goes back at the beginning of point 6.
7
speech time:sss
Type the new “SPEECH TIME” (up to 3 digits in seconds) or leave unchanged (if existing). This is the du-
ration of the conversation time. When the speech time expire the conversation is automatically closed.
Press “ENTER” button.
8
door time:ddd
Type the new “DOOR TIME” or leave unchanged (if existing). This is the duration of door open
relay actuation. The relay will activate for the time specified by this value.
Press “ENTER” button.
9
device n:n
Type the new “DEVICE NO” or leave unchanged (if existing). This is an unique identifier for the
panel. It is used for camera recall operation (see videophone instructions).
Press “ENTER” button.
10
1=eng, 2=it, 3=esp
4=por, 5=fr, 6=ger
The display shows the selected language by the relevant number underlined. Type the num-
ber relevant to the required language or leave it unchanged.
Press “ENTER” button.
11
1=no, 2=st, 3=cmb
speech board
The display shows the selected speech board operation mode
4
by the relevant number under-
lined. Leave unchanged or type the number relevant to the operating mode required.
Press “ENTER” button.
12
test mode:
1-2, enter=end
Choose the required test mode
5
to test or press “ENTER” to exit programming.
Press “ENTER” button.