20
SHOWER VALVE
The shower valve can be accessed from the rear of
the shower and is located on the central tower.
The valve is divided into three parts that are joined
together.
The uppermost part is the divertor. There are
three connections able to be made here. One to
the overhead shower from the outlet pointing
upwards, another to connect to the body jets and
the third connects to the hand shower/riser bar
water inlet.
When making the connections,
ensure they are water tight. Check
all pre-fi tted hoses as these may
only be hand tight during
manufacture.
The middle part of the valve handles the water on
and off . There are no connections to be made here.
The lower part of the valve has three connections
to be made. The HOT and COLD water supplies
from you property connect to the outermost
connections - ENSURE THE FEEDS ARE THE
CORRECT WAY ROUND. The third connection is a
cold water supply from the valve and connects to
the WATER IN on the steam generator.
REMOVE THE WHITE PLASTIC BOX SECTION THAT
MAY BE COVERING THE VALVE ACCESS AT THE
REAR - THIS IS FOR TRANSPORT PURPOSES ONLY
AND IS NO LONGER NEEDED.
Cold Water IN from the shower valve
connects to the Steam Generator (your
steam generator may look diff erent
than the image opposite, but the
connections are marked the same).
The STEAM OUT connects to the rear of
the Steam Pod via the INSULATED HOSE
to supply Steam into the shower.
Waste/Drain allows un-used water in
the generator after it is used, to exit into
the underside of the Plug Waste via a
thin grey hose.