background image

Manual Skylla with universal input  

1.3 

Warnings 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
The cover of the battery charger may only be removed by a qualified 
technician.

 

Before obtaining access to the battery charger the mains 

supply circuit must be disconnected. 

 
Explosive gasses can occur during charging a lead-acid battery. 
Prevent flames and sparks. 
Provide adequate ventilation during charging. 

 
The battery charger can not be used to charge non-rechargeable 
batteries. 

 

 

 
The on/off switch at the front of the cabinet does not switch off the 
mains supply. 
 

 

 
Disconnect  the  mains  supply  before  making  or  breaking  the 
connections to the battery. 
 

 

 
Do  not  use  the  voltage  sense  facility  in  combination  with  the 
diode-splitter  compensation.  This  will  raise  the  output  voltage, 
which could damage the battery. 

 
There is a dangerous voltage present on some of the metal parts 
inside the battery charger. 

 

 

 

The  battery  charger  is  NOT  protected  against  reverse  battery 
polarity. ("+" connected to "-" and "-" connected to "+").

   

Follow  the  installation  procedure.  The  warranty  expires  when  the 
battery charger becomes defective due to reverse battery polarity. 

Summary of Contents for 24/30

Page 1: ...USER MANUAL SKYLLA TG 24 30 with Universal Input SKYLLA TG 24 50 with Universal Input SKYLLA TG 24 100 G with Universal Input SKYLLA TG 24 100 victron energie C H AR G ER...

Page 2: ......

Page 3: ...ANYONE FOR SPECIAL COLLATERAL INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH OR ARISING OUT OF PURCHASE OR USE OF THESE VICTRON ENERGY PRODUCTS THE SOLE AND EXCLUSIVE LIABILITY TO VICTRON ENER...

Page 4: ...3 Adjusting the equalize charging mode time 18 4 4 Diode splitter charge voltage compensation 18 4 5 Traction battery compensation 19 4 6 Use as a power supply 19 4 7 Use of a temperature sensor 19 4...

Page 5: ...ystem can consist of a Victron Energy inverter a Victron Energy battery charger if required a Victron Energy Mains Manager and batteries with sufficient capacity Our equipment can be used in numerous...

Page 6: ...ff switch at the front of the cabinet does not switch off the mains supply Disconnect the mains supply before making or breaking the connections to the battery Do not use the voltage sense facility in...

Page 7: ...TG charger commences charging in the boost charge mode In this mode the battery is charged until the battery voltage reaches the boost voltage At this point the battery is charged to approximately 80...

Page 8: ...e a starter battery You can use this battery for starting machines like a boat engine for this application The Skylla TG charger has a stabilised output voltage Therefore the Skylla TG charger can als...

Page 9: ...the output voltage approaches 0 Volt The battery charger resumes normal operation when the short circuit is removed The short circuit current can also be reduced by the Victron Energy COV panel Input...

Page 10: ...LED illuminates continuously The charger resumes operation when the internal temperature is restored within limits Voltage sense protection When the voltage sense facility is used the charger automat...

Page 11: ...he earth screw to the earth of the mains Mobile applications a vehicle a car or a caravan Connect the earth screw to the frame of the vehicle Connecting the battery The connections between the Skylla...

Page 12: ...ative battery cable to the connection tool see illustration 3 Check if the green led illuminates see illustration 3 If not the positive and negative battery cables have been reversed Disconnect the co...

Page 13: ...charger Remove the front of the battery charger to access the AC input connector Connect the mains PE cable green yellow to the AC input connector located on the circuit board see illustration 4 Conne...

Page 14: ...of the battery the charger will start in the boost charge mode or at float charge mode If the battery is not full the boost led illuminates and the charger will start boost charging the battery A dip...

Page 15: ...charger does not have to be switched off and the batteries can stay connected to the battery charger 3 3 Maintenance The Skylla charger does not require any specific maintenance However an annual che...

Page 16: ...the battery charger Adjustments can be made by means of turning a potentiometer or by changing the position of a switch on the DIP switch See illustration 7 for the location of the DIP switch and the...

Page 17: ...set float and boost voltage The boost voltage is always higher than the float voltage These charging voltages are the recommended values from almost every battery manufacturer Before adjusting the cha...

Page 18: ...duration of the equalize charge mode can be changed to fit the specifications of the battery The duration of the equalize charge mode can be set to 0 4 8 or 12 hours When selecting 0 hours the charger...

Page 19: ...the above mentioned procedure the output voltage range is limited When the full output voltage range is required please contact your Victron Energy dealer See chapter 6 3 for details 4 7 Use of a tem...

Page 20: ...s Connect a red 0 75 mm2 wire to the positive battery pole and the Vse connector of the charger see illustration 8 Connect a black 0 75 mm2 wire between the negative pole of the battery and the Vse co...

Page 21: ...ging current of 30A 50A or 100A according to the model can be limited with an external panel This panel the Victron Energy COV panel contains an adjustable potentiometer Limiting the maximum charging...

Page 22: ...ol to the POT and POT connector 4 12 Connecting a remote on off switch A remote switch can be connected to the charger so the charger can be switched on and off from a remote location To operate the s...

Page 23: ...e between the connection of the voltmeter and VM at the remote connector Connect a red wire between the connection of the voltmeter and VM at the remote connector Connect the mains voltage 4 15 Connec...

Page 24: ...ut fuses The battery is being overcharged The battery charger is set into the permanent boost charge mode Deselect the permanent boost DIP switch Rboost The boost charge voltage is set to a wrong valu...

Page 25: ...on EN 55014 1993 EN 61000 3 2 1995 EN 61000 3 3 1995 Immunity EN 55104 1995 Vibration IEC 68 2 6 1982 Safety GL approval EN 60335 2 29 1991 Environmental category C EMC 1 Certificate no 54 758 08HH 6...

Page 26: ...n for traction battery via DIP switch 2 0 V 2 0 V 2 0 V Maximum output current 30A 50A 100A Output current range 0 30A 0 50A 0 100A Output voltage ripple measured with a 30A 50A or 100A resistive load...

Page 27: ...ght including box 6 4 Kg 10 5 Kg Input 230Vac connection Connection block suitable for wires up to 4 mm Connection block suitable for wires up to 4 mm Battery connection M8 bolts M8 bolts Earth connec...

Page 28: ...al input victron energy b v Pallas TG 12 50 Skylla TG 24 30 24 30 110Vac Skylla TG 24 50 and Titan 48 25 dimensions drawing no TI010000 date 120204 revision 0002 220 15 7 8 6 250 25 200 140 90 365 309...

Page 29: ...kylla with universal input 29 victron energy b v Skylla TG 24 80 24 100 and Titan 48 50 dimensions drawing no TI020000 date 220703 revision 01 220 8 6 250 200 250 25 25 23 365 309 200 All measurements...

Page 30: ...Skylla with universal input Victron Energy B V The Netherlands Phone 31 0 36 535 97 00 Fax 31 0 36 531 16 66 E mail sales victronenergy com Internet site http www victronenergy com Version rev03 Date...