12
Manual Skylla with universal input
- starter battery connection
+ starter battery connection
Green led
Negative battery connection
Output fuses
Positive battery connection
Red led
Connection tool
The battery connection sequence
Check if the charger is switched off and if the mains supply is disconnected.
Remove the front of the battery charger to access the battery connections.
If not placed, place the connection tool to the negative battery connection (-) of the
charger, see illustration 3.
Connect the positive battery-cable (+) to the positive battery connection terminal on
the charger printed circuit board, see illustration 3.
Hook the negative battery-cable (-) to the connection tool, see illustration 3.
Check if the green led illuminates, see illustration 3. If not the positive and negative
battery cables have been reversed.
Disconnect the connection tool and connect the negative battery cable (-).
The battery disconnection sequence
Switch off the charger.
Disconnect the mains supply.
Disconnect the negative battery-cable.
Disconnect the positive battery-cable.
The Skylla is NOT protected against reverse battery polarity.
("+" connected to "-" and "-" connected to "+").
Follow the installation procedure. The warranty expires when the
Skylla becomes defective due to reverse polarity.
Disconnect the mains supply
before making or breaking
connections to the battery.
Illustration 3.
Location of the battery
connections
The on/off switch at the
front of the cabinet does not
switch off the mains supply.