Manual Skylla with universal input
13
Connecting the starter battery
The starter battery has to be connected using wire with a core of at least 1.5 mm
2
.
Connect the positive (+) battery-pole to the right side of the starter battery
connector, see illustration 3.
Connect the negative (-) battery-pole to the left side of the starter battery connector,
see illustration 3.
Connecting the mains
Check if the battery is already connected to the charger.
Remove the front of the battery charger to access the AC input connector.
Connect the mains PE cable (green/yellow) to the AC input connector located on the
circuit board, see illustration 4.
Connect the mains neutral cable (blue) to the AC input connector.
Connect the mains line cable (brown) to the AC input connector.
Plug the mains cable into the mains socket. Make sure that the mains socket is
connected to earth. The connection to the earth of the mains has to be according to
applicable safety standards.
Illustration 4.
Location of the
AC input connector.
AC input connector
N L
PE connection
neutral connection
line connection
Summary of Contents for 24/30