Manual Skylla with universal input
25
6.
TECHNICAL SPECIFICATIONS
6.1
General
Switch on behaviour
Charger can switch on under every load
Temperature range
0 °C until +40
°
C,
decreasing output power if temperature > +40
º
C
EMC
According Council Directive 89/336 EEG
Emission
EN 55014 (1993)
EN 61000-3-2 (1995)
EN 61000-3-3 (1995)
Immunity
EN 55104 (1995)
Vibration
IEC 68-2-6 (1982)
Safety
GL approval
EN 60335-2-29 (1991)
Environmental category C, EMC 1
Certificate no 54 758 – 08HH
6.2
Input
Input voltage range
90 - 265 Vac,
full output power available
Frequency range
45 - 65 Hz,
full output power available
Maximum Input current
At 90V ac input voltage :
Model:
24/30
24/50
24/100
12A at 30V / 30A
20A at 30V / 50A
40A at 30V / 100A
Cos phi / power factor
1,0