background image

 

EN 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

G e b r u i k s a a n w i j z i n g  

          

Pagina

 

2

 

U s e r s   m a n u a l  

Page 16 

G e b r a u c h s a n w e i s u n g  

Seite 30  

 

HDC-

series 

S o f t w a r e   V 2 2 . 0 1  

 

DC

-D

C

 

C

H

A

R

G

E

R

 

C

O

N

V

E

R

T

E

R

 

N L  

E N  

D E 

 

Available models : 
 
HDC 1212-40  

Summary of Contents for HDC Series

Page 1: ...eb rui ks aanw ijzi ng Pagina 2 Users m an u al Page 16 Geb rau chs anw eisu n g Seite 30 HDC series S o f t w a r e V 2 2 0 1 D C D C C H A R G E R C O N V E R T E R NL EN DE Available models HDC 121...

Page 2: ...terne MPPT laadregelaar voor het aansluiten van een zonnepaneel max 45Vdc 600Watt Via deze tweede solar ingang wordt zo de accessoire accu tevens opgeladen op het moment dat de motor niet draait De HD...

Page 3: ...s aan te passen via het instellingenmenu Deze is met stappen van 5Amp instelbaar tussen 10 40Amp Af fabriek staat deze ingesteld op 40Amp Onderspanning accubewaking Verbruikt de laadomvormer meer stro...

Page 4: ...an de omvormer toch te hoog oplopen dan zal de omvormer zichzelf uitschakelen De omvormer zal weer automatisch opstarten als deze voldoende is afgekoeld Als de omvormer is uitgevallen op basis van int...

Page 5: ...taccu en de HDC 1212 40 is 1 5 meter 40 Amp x 1 5 x 0 2 12 mmq Mocht de maximale laadstroom via de instellingen aangepast worden dan kan deze waarde in de berekening genomen worden Voor de kabeldikte...

Page 6: ...het zonnepaneel indien aanwezig 4 Verbinding maken tussen aansluiting en massa voertuig 5 D verbinding maken tussen dynamo en HDC omvormer Veelal hebben dynamo s geen D meer Maak in dat geval gebruik...

Page 7: ...lok EBL welke de complete energie voorziening aanstuurt Dit is daarom van grote invloed op de plaatsing van de HDC omvormer Twee mogelijkheden 1 HDC parallel aan EBL voorkeur Belangrijk maak het D aan...

Page 8: ...lithium of Custom program kan de hoofd laadspanning en de druppellaadspanning gepersonaliseerd worden Bij het laden van een lithium LiFePO4 accu dient altijd voor de setting LI gekozen te worden Deze...

Page 9: ...blijven staan Druk op next om naar de volgende stap te gaan Indien er tussentijds voor 20 sec geen toets meer gebruikt is dan zal de laadomvormer uit de instelmodus keren 01 Instellen van de onderspan...

Page 10: ...ng treden Dit zal dus zijn als de motor draait ofwel het sleutelcontact in de on positie is Als de D aanwezig is zal in het display priority verschijnen Onder in het display verschijnt een verbinding...

Page 11: ...ing De ingestelde laadspanning blijft constant en de laadstroom zal terug lopen naar mate de accu vol wordt Als de minimale stroomgrens is bereikt zal de omvormer omschakelen naar druppellading De acc...

Page 12: ...nde laadomvormer DC ofwel solar PV 2 Ingangsspanningsniveau 3 Weergave eventuele foutcode 4 Weergave uitgangwaarde Laadfase Laadstroom Laadspanning 5 D aanwezig 6 Betreffende ingang aangesloten 7 Laad...

Page 13: ...gezakt is Laat eventueel de dynamo anders afstellen Error E3 Ingangspanning op solar input te laag Als de ingangsspanning weer voldoende is gestegen dan zal het laadproces automatisch worden gestart...

Page 14: ...om leveren Er staat andere grote verbruikers aan en of de dynamo is te licht voor de toepassing In de hoofdlading levert de laadrege laar Solar input niet zijn volledige laadstroom Zonnepanelen lever...

Page 15: ...sturen naar het adres op de achterzijde van deze gebruiksaanwijzing De omvormer dient gefrankeerd opgestuurd te worden Op deze omvormers wordt 2 jaar garantie verleend vanaf verkoopdatum en alleen op...

Page 16: ...charge controller for connecting a solar panel max 45Vdc 600Watt The accessory battery is also charged via this second solar input when the engine is not running The HDC converter is therefore a hybr...

Page 17: ...ired charging current can be adjusted via the settings menu This is in steps of 5Amp adjustable between 10 40Amp Factory setting is 40Amp Undervoltage battery monitoring If the charging converter cons...

Page 18: ...nevertheless rises too high the converter will switch itself off The converter will restart automatically when it has cooled down sufficiently If the converter has failed due to internal temperature...

Page 19: ...imum charging current is adjusted via the settings this value can be included in the calculation For the cable thickness for the ignition D and ground a minimum of 1 5mmq can be maintained Fuse To pro...

Page 20: ...longer have D In that case use the ignition lock After assembly check whether all cables are connected to the correct poles Reverse polarity can damage the converter If in exceptional cases you still...

Page 21: ...on the placement of the HDC converter Two options 1 HDC parallel to EBL preferred Important Disable the EBL s D controlled cutoff relay 2 HDC parallel to the EBL in combination with an external relay...

Page 22: ...rging profiles LI lithium or Custom program the main charging voltage and the trickle charging voltage can be personalized When charging a lithium LiFePO4 battery the LI setting should always be selec...

Page 23: ...main in memory Press next to go to the next step If interim for 20 sec no more keys have been pressed the device will exit the setting mode 01 Setting the undervoltage monitoring 11 5Vdc 12 5Vdc 02 Se...

Page 24: ...operation This will be when the engine is running or the key switch is in the on position If the D is present the display will show priority A connection between the alternator symbol and battery appe...

Page 25: ...switches to absorption The set charging voltage remains constant and the charging current will decrease as the battery becomes full When the minimum current limit is reached the converter will switch...

Page 26: ...charging converter DC or solar PV 2 Input voltage level 3 Display any error code 4 Output value display Charing phase Charging current Charging voltage 5 D present 6 Relevant input connected 7 Chargi...

Page 27: ...ently again the charging process will be started automatically Error E4 Input voltage on solar input too high When the input voltage has dropped sufficiently again the charging process will be started...

Page 28: ...e charge controller Solar input does not deliver its full charge current Solar panels produce too little energy to provide the full charging current The charge controller depends on the panel yield Th...

Page 29: ...r send it directly to the address on the back of this manual The converter must be sent prepaid These converters are warranted for 2 years from the date of sale on parts and labor for repair only The...

Page 30: ...ler zum Anschluss eines Solarmoduls max 45VDC 600 Watt ausgestattet ber diesen zweiten Solar Eingang wird auch die Zubeh r batterie geladen wenn der Motor nicht l uft Der HDC Wandler ist also ein hybr...

Page 31: ...stellbar zwischen 10 40 Amp Dies ist werkseitig auf 40 Ampere eingestellt Unterspannung Batterie berwachung Nimmt der Lade Wandler mehr Strom aus der ersten Batterie auf als die Lichtmaschine liefert...

Page 32: ...ur des Wandler dennoch zu stark an dann schaltet das Ger t ab Der Wandler startet automatisch neu wenn er ausreichend abgek hlt ist Wenn der Wandler aufgrund der Innentemperatur ausgefallen ist wird d...

Page 33: ...r Abstand zwischen Starterbatterie und HDC 1212 40 betr gt 1 5 Meter 40 Ampere x 1 5 x 0 2 12 mmq Wird der maximale Ladestrom ber die Einstellungen angepasst kann dieser Wert in die Berechnung mit ein...

Page 34: ...m Solarpanel falls vorhanden 4 Verbindung zwischen Anschluss und Massefahrzeug herstellen 5 D Verbindung zwischen Lichtmaschine und HDC Wandler Lichtmaschinen haben oft kein D mehr Verwenden Sie in di...

Page 35: ...usgestattet der die komplette Energieversorgung steuert Dies hat daher gro en Einfluss auf die Platzierung des HDC Wandlers Zwei Optionen 1 HDC parallel zu EBL bevorzugt Wichtig Deaktivieren Sie das D...

Page 36: ...oder Custom program k nnen die Hauptladespannung und die Erhaltungsladespannung personalisiert werden Beim Laden eines Lithium LiFePO4 Akkus sollte immer die Einstellung LI gew hlt werden Diese Einst...

Page 37: ...te Wert gespeichert Dr cken Sie Next um zum n chsten Schritt zu gelangen Wenn f r 20 sek keine weitere Tastenbet tigung erfolgt verl sst der Wandler den Einstellmodus 01 Einstellen der Unterspannungs...

Page 38: ...Dies ist der Fall wenn der Motor l uft oder der Schl sselschalter auf Ein steht Wenn D vorhanden ist zeigt das Display Priority an Als Hinweis auf den laufenden Ladevorgang erscheint am unteren Rand d...

Page 39: ...den um Die eingestellte Ladespannung bleibt konstant und der Ladestrom nimmt ab wenn der Akku voll wird Wenn die minimale Stromgrenze erreicht ist schaltet der Wandler auf Erhaltungsladung um Die Batt...

Page 40: ...dewandler DC oder Solar PV 2 Eingangsspannungspegel 3 Beliebigen Fehlercode anzeigen 4 Ausgangswertanzeige Ladephase Ladestrom Ladespannung 5 D vorhanden 6 Relevanter Eingang verbunden 7 Ladevorgang l...

Page 41: ...nen falls Lichtmaschine anders einstellen lassen Fehler E3 Eingangsspannung am Solareingang zu niedrig Wenn die Eingangsspannung wieder ausreichend ange stiegen ist wird der Ladevorgang automatisch ge...

Page 42: ...gro e Verbraucher sind eingeschaltet und oder die Lichtmaschine ist zu leicht f r die Anwendung In der Hauptladung liefert der Lade regler Solar input nicht seinen vollen Ladestrom Solarmodule produz...

Page 43: ...zur ckgeben oder direkt an die Adresse auf der R ckseite dieser Anleitung senden Der Wandler muss frachtfrei verschickt werden Diese Wandler haben eine 2 j hrige Garantie ab Verkaufsdatum und nur auf...

Page 44: ...44...

Page 45: ...lar panels 600W CHARGING FEATURES Charging characteristic IUoUoe 3 phases Voltages charge setting GEL 14 2V 13 8V Voltages setting WET 14 4V 13 5V Voltages setting AGM 14 8V 13 8V Voltages setting LI...

Page 46: ...Xenteq BV Banmolen 14 5768 ET Meijel NL Tel 0031 0 77 4662067 info xenteq nl www xenteq nl V22 01B...