45
HDC 1212-40
Input voltage nominal
12Vdc
Output voltage nominal
12Vdc
Charging current, adjustable
10 ~ 40Amp, factory setting 40Amp
CHARGING CONVERTER
Charging activation
via D+
Undervoltage protection, adjustable
11,5 ~ 12,5V, factory seting 11,7V
Undervoltage restart, adjustable
12,5 ~ 13,5V, factory setting 12,8V
Overvoltage protection
15,8V
Overvoltage restart
15V
MPPT CHARGE CONTROLLER
Input solar
15 ~ 45 Vdc
Overvoltage protection
45V
Overvoltage restart
44V
Undervoltage protection
15V
Undervoltage restart
15,5V
Max. power solar panels
600W
CHARGING FEATURES
Charging characteristic
IUoUoe, 3 phases
Voltages, charge setting GEL
14,2V / 13,8V
Voltages setting WET*
14,4V / 13,5V
Voltages setting AGM
14,8V / 13,8V
Voltages setting LI, adjustable
Bulk: 12,6V ~ 14,8V (default 14,4V)
Float: non / 13,0V ~ 14,8V (default non)
Voltages setting Custom, adjustable
Bulk: 13,8V ~ 14,8V
Float: 13,0V ~ 14,0V
GENERAL
Efficiency
Max 90%
Rimpel
≤
50mA
Input connection
Screw connection
Output connection
Screw connection
Galvanically isolated
No
Parallel connectable
No
Cooling
Fan
IP classification
IP 205
Dimensions lxwxh
22,2 x 16,4 x 7,4 cm
Weight
1,3 kg
All specifications are based on 20
⁰
C
*= factory setting
All dates subject to change
All mentioned voltages have a tolerance of 0.1 Volt