4
VE106 Groove-N-Go Tool
VE106 GROOVE-N-GO
CONTAINER CONTENTS
POWER REQUIREMENTS
Power must be supplied to the drive motor
through a safety foot switch to ensure safe
operation. Make sure the drive motor is
grounded properly in accordance with Article
250 of the National Electrical Code.
If an extension cord is required, refer to the
“Extension Cord Requirements” section
below for cord sizes.
EXTENSION CORD REQUIREMENTS
When pre-wired outlets are not available and
an extension cord must be used, it is impor-
tant to use the proper cord size (i.e. Conduc-
tor Size American Wire Gauge). Cord size
selection is based upon tool rating (amps)
and cord length (feet). Cord sizes (gauges)
thinner than required will cause significant
voltage drop at the drive motor while the tool
is operating. Voltage drops may cause dam-
age to the drive motor and can result in im-
proper tool operation.
NOTE:
It is acceptable
to use a heavier cord size (gauge) than what
is required.
The required cord sizes (gauges) for cord
lengths up to and including 100 feet (30 m)
are listed in the table below. Use of extension
cords longer than 100 feet (30 m) must be
avoided.
Qty.
Description
1
Tool Head Assembly with Cart
3
Adjustable Legs (Secured in Leg
Storage Tubes of Cart)
1
Lower Roll/Main Shaft for 1
1
/
4
- 3-inch
Carbon Steel Pipe *
1
Safety-Foot-Switch Storage Box
1
Safety Foot Switch (Located Inside
Storage Box)
2
Operating and Maintenance Instructions
Manual
1
VE106 Groove-N-Go Repair Parts List
1
3
/
8
-inch Square-Drive Ratchet (10 inches
Long)
-
Spare Shear Pins
-
Depth Gauges for 1
1
/
4
- 6-inch Schedule
5, Schedule 10, and Schedule 40
Carbon Steel Pipe
1
3
/
16
-inch Hex Key Allen Wrench
1
Go/No-Go Pipe Tape
1
11 oz. can of Dow Corning G-n
Mechanical Assembly Spray
* The lower roll/main shaft for 4 – 6-inch carbon
steel pipe is installed in the head assembly
NOTE:
Optional items, such as roll sets for groov-
ing stainless steel pipe and copper tubing, may be
shipped separately.
DANGER
• To reduce the risk of electric
shock, check the electrical
source for proper grounding.
• Before performing any mainte-
nance on the tool, disconnect
the power cord from the electri-
cal source.
Failure to follow these instructions could result in
death or serious personal injury.
Drive Motor
Rating
Volts (Amps)
Cord Lengths
25 feet
(8 m)
50 feet
(15 m)
100 feet
(31 m)
110
12 gauge
12 gauge
10 gauge
(12)
220
14 gauge
12 gauge
10 gauge
(6)
TM-VE106 3736 Rev_B.fm Page 4 Monday, May 9, 2005 12:02 PM